Changes for page Troubleshooting
Last modified by jadomatis on 2026/09/07 13:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -73,72 +73,21 @@ 73 73 For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 74 74 75 75 76 -= X1 Safety Interface-Emergency-Stop Circuit=76 += X1 and X2 Diagnostic Boundary = 77 77 78 78 (% class="box errormessage" %) 79 79 ((( 80 -**Qualified personnel only: **The diagrams identifythedocumented interfaceconnections; theyarenot instructionsto probeor rewire anenergizedsystem. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require isolationand personnel authorized for the delivered integration.80 +**Qualified personnel only: **The following signal map helps identify where a fault belongs. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require the system to be isolated and may be performed only by personnel authorised for the delivered integration. 81 81 ))) 82 82 83 -(% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling. 84 -\\ 83 +[[image:1788773598823-721.png]] 85 85 86 -[[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]] 87 87 86 +|**Interface**|**Relevant signals**|**Diagnostic meaning** 87 +|X1 safety|Pins 1-4: dual emergency-stop circuits; 5-6: acknowledgement|Both channels and the approved acknowledgement must be valid before operation. 88 +|X1 shutter|Pins 7-10: dual shutter circuits; 11-12: acknowledgement|Opening the protective enclosure must interrupt the shutter circuit. Never bypass either channel. 89 +|X1 control|13: +24 V; 14: START; 15: STOP|Check the host command sequence only after the safety states are valid. 90 +|X1 status|16: E-stop; 17: SHUTTER; 18: READY; 19: BUSY; 20: END|Record which output is absent or changes first. Active outputs provide 24 V; maximum output current is 250 mA. 91 +|X2 axes|Direction/step for X, Y, Z, R; zero inputs|A motion or reference fault may belong to the host mechanics, axis wiring, limit/reference input, or configuration. 88 88 89 -Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition. 90 -\\ 91 - 92 -[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]] 93 - 94 - 95 -= X1 Safety Interface - Shutter Circuit = 96 - 97 -The shutter connection also uses two external safety channels: circuit 1 at X1.7/X1.8 and circuit 2 at X1.9/X1.10. Opening the protective enclosure must interrupt the shutter circuit. A closed and validated shutter circuit permits active mode; it does not by itself command a marking cycle. 98 98 99 - 100 -[[**Example: dual shutter safety circuits at X1.7-X1.10.**>>image:1788776328447-524.png]] 101 - 102 - 103 -Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task. 104 -\\ 105 - 106 -[[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]] 107 - 108 -(% class="box warningmessage" %) 109 -((( 110 -**Diagnostic meaning: **If either emergency-stop or shutter channel is open, inconsistent, or not acknowledged, LASER READY may remain absent. Never bridge a channel to prove this diagnosis; use the host safety-module indications and approved electrical test procedure. 111 -))) 112 - 113 - 114 -= X1 Production and Status I/O = 115 - 116 -After the safety circuits are valid, use the documented X1 command and status sequence to localise a control fault. Record which state is missing or which output changes first. 117 - 118 -|**Pin group**|**Documented function**|**Diagnostic use** 119 -|X1.13-X1.15|+24 V input supply; External START; External STOP|If START has no effect, confirm LASER READY before checking the host command. An active STOP or missing start condition can stop a cycle. 120 -|X1.16-X1.17|Emergency-stop status; SHUTTER status|These show whether the safety chain and shutter permission have reached the expected state. 121 -|X1.18-X1.20|LASER READY; LASER BUSY; LASER END|Use the transition order to distinguish a missing ready condition, a cycle that never started, or a cycle that did not complete normally. 122 -|X1.21-X1.24|Inputs 4 and 5; Outputs 4 and 5|Their assigned use depends on the delivered integration. Check the approved electrical documentation before interpreting them. 123 -|X1.25|GND for outputs|Active outputs supply 24 V and are evaluated against this output ground. The documented maximum output current is 250 mA. 124 - 125 - 126 - 127 -== Expected Diagnostic Sequence == 128 - 129 -1. Verify both emergency-stop channels and the required acknowledgement. 130 -1. Verify both shutter channels, the guard condition, and shutter acknowledgement. 131 -1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY. 132 -1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence. 133 -1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration. 134 - 135 -(% class="box warningmessage" %) 136 -((( 137 -**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine. 138 -))) 139 - 140 - 141 - 142 -= X2 Axis Interface = 143 - 144 -X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide.
- 1788775595167-399.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -45.5 KB - Content
- 1788775764610-963.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.3 KB - Content
- 1788776328447-524.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -45.6 KB - Content
- 1788776541211-163.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.8 KB - Content