137 137  **Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine.
138 138  )))
139 139  
140 +
141 +
140 140  = X2 Axis Interface =
141 141  
142 -X2 is the 25-pin Sub-D axis interface. The manual groups direction and step outputs for X, Y, Z, and R with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energised probing guide.
144 +X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide.
145 +
146 +(% class="table-condensed table-striped" style="width:604px" %)
147 +|=(% style="width: 92px;" %)Pin|=(% style="width: 160px;" %)Direction|=(% style="width: 350px;" %)Description
148 +|(% style="width:92px" %)1|(% style="width:160px" %)Output|(% style="width:350px" %)Direction X
149 +|(% style="width:92px" %)2|(% style="width:160px" %)Output|(% style="width:350px" %)Step X
150 +|(% style="width:92px" %)3|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Y
151 +|(% style="width:92px" %)4|(% style="width:160px" %)Output|(% style="width:350px" %)Step Y
152 +|(% style="width:92px" %)5|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Z
153 +|(% style="width:92px" %)6|(% style="width:160px" %)Output|(% style="width:350px" %)Step Z
154 +|(% style="width:92px" %)7|(% style="width:160px" %)Output|(% style="width:350px" %)Direction R
155 +|(% style="width:92px" %)8|(% style="width:160px" %)Output|(% style="width:350px" %)Step R
156 +|(% style="width:92px" %)9|(% style="width:160px" %)Output|(% style="width:350px" %)Zero X
157 +|(% style="width:92px" %)10|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
158 +|(% style="width:92px" %)11|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Y
159 +|(% style="width:92px" %)12|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
160 +|(% style="width:92px" %)13|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Z
161 +|(% style="width:92px" %)14|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
162 +|(% style="width:92px" %)15|(% style="width:160px" %)Input|(% style="width:350px" %)Zero R
163 +|(% style="width:92px" %)16|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
164 +|(% style="width:92px" %)17|(% style="width:160px" %)Output|(% style="width:350px" %)GND
165 +|(% style="width:92px" %)18|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
166 +|(% style="width:92px" %)19|(% style="width:160px" %)Output|(% style="width:350px" %)+5V supply
167 +|(% style="width:92px" %)20|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
168 +|(% style="width:92px" %)21|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
169 +|(% style="width:92px" %)22|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
170 +|(% style="width:92px" %)23|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
171 +|(% style="width:92px" %)24|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
172 +|(% style="width:92px" %)25|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
173 +
174 +
175 +
176 += Diagnosing an X2 Axis Fault =
177 +
178 +(% class="box errormessage" %)
179 +(((
180 +**Before commanding movement: **Confirm that the area is clear, the workpiece and fixture are secure, the permitted travel is known, and the host machine is in its approved setup or service state. Stop immediately if movement is unexpected or mechanically obstructed.
181 +)))
182 +
183 +(% class="table-condensed table-striped" style="width:901px" %)
184 +|**Axis**|(% style="width:242px" %)**Direction output**|(% style="width:227px" %)**Step output**|(% style="width:278px" %)**Zero/reference signal**
185 +|X|(% style="width:242px" %)X2.1|(% style="width:227px" %)X2.2|(% style="width:278px" %)X2.9
186 +|Y|(% style="width:242px" %)X2.3|(% style="width:227px" %)X2.4|(% style="width:278px" %)X2.11
187 +|Z|(% style="width:242px" %)X2.5|(% style="width:227px" %)X2.6|(% style="width:278px" %)X2.13
188 +|R|(% style="width:242px" %)X2.7|(% style="width:227px" %)X2.8|(% style="width:278px" %)X2.15
189 +
190 +
191 +
192 +== Use the Signal Groups to Localise the Fault ==
193 +
194 +* No commanded movement: identify the relevant direction/step pair - X2 pins 1-2 for X, 3-4 for Y, 5-6 for Z, or 7-8 for R - then check the approved axis configuration and host mechanics.
195 +* Axis will not reference: inspect the corresponding zero signal - X2.9 for X, X2.11 for Y, X2.13 for Z, or X2.15 for R - using the approved service procedure.
196 +* Unexpected direction, travel, repeated reference failure, or mechanical obstruction: stop movement and isolate the system. Do not continue jogging the axis to overcome the condition.
197 +
198 +(% class="box warningmessage" %)
199 +(((
200 + **Additional X2 pins: ** X2.17 is GND and X2.19 is the +5 V supply; the remaining listed pins are not connected. Voltage checks, connector work, and changes to axis wiring or configuration are service tasks for authorized personnel.
201 +)))
202 +
203 += Operator Checkpoints on the Laser Rack =
204 +
205 +[[image:1788778758156-557.png]]
206 +
207 +//Figure 6 - External operator and connection points. Do not remove covers or open the laser rack.//
208 +
209 +* Check the rear main switch, front laser key switch, status indicator, and approved host/AnyMarker connection.
210 +* Keep the cooling vents unobstructed. Stop operation if airflow is restricted, heat accumulates, or an abnormal smell or sound is present.
211 +* Visually inspect accessible cables and connectors without opening covers or disturbing the validated wiring. Isolate and escalate damage, looseness, overheating, or contamination.