Changes for page Troubleshooting
Last modified by jadomatis on 2026/09/07 13:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -62,81 +62,4 @@ 62 62 **Do not tune blindly: **Power, speed, hatch spacing, focus, and font can be possible causes. Their combined effect depends on the laser source, optics, material, geometry and job. Use released parameters and requalify intentional changes. See the shared **[[Marking Methods article>>doc:Marking Methods.WebHome]]** for cross-system process guidance. 63 63 ))) 64 64 65 - 66 - 67 -= AnyMarker or Controller Communication = 68 - 69 -* Record the message before closing AnyMarker or restarting the controller. 70 -* Confirm the approved USB or Ethernet connection and the expected Auto-Light device selection without disconnecting cables during an active cycle. 71 -* If communication repeatedly drops, stop production and have the workstation, cable, controller and network path checked by authorised personnel. 72 - 73 -For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 74 - 75 - 76 -= X1 Safety Interface - Emergency-Stop Circuit = 77 - 78 -(% class="box errormessage" %) 79 -((( 80 -**Qualified personnel only: **The diagrams identify the documented interface connections; they are not instructions to probe or rewire an energized system. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require isolation and personnel authorized for the delivered integration. 81 -))) 82 - 83 -(% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling. 84 -\\ 85 - 86 -[[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]] 87 - 88 - 89 -Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition. 90 -\\ 91 - 92 -[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]] 93 - 94 - 95 -= X1 Safety Interface - Shutter Circuit = 96 - 97 -The shutter connection also uses two external safety channels: circuit 1 at X1.7/X1.8 and circuit 2 at X1.9/X1.10. Opening the protective enclosure must interrupt the shutter circuit. A closed and validated shutter circuit permits active mode; it does not by itself command a marking cycle. 98 98 99 - 100 -[[**Example: dual shutter safety circuits at X1.7-X1.10.**>>image:1788776328447-524.png]] 101 - 102 - 103 -Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task. 104 -\\ 105 - 106 -[[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]] 107 - 108 -(% class="box warningmessage" %) 109 -((( 110 -**Diagnostic meaning: **If either emergency-stop or shutter channel is open, inconsistent, or not acknowledged, LASER READY may remain absent. Never bridge a channel to prove this diagnosis; use the host safety-module indications and approved electrical test procedure. 111 -))) 112 - 113 - 114 -= X1 Production and Status I/O = 115 - 116 -After the safety circuits are valid, use the documented X1 command and status sequence to localise a control fault. Record which state is missing or which output changes first. 117 - 118 -|**Pin group**|**Documented function**|**Diagnostic use** 119 -|X1.13-X1.15|+24 V input supply; External START; External STOP|If START has no effect, confirm LASER READY before checking the host command. An active STOP or missing start condition can stop a cycle. 120 -|X1.16-X1.17|Emergency-stop status; SHUTTER status|These show whether the safety chain and shutter permission have reached the expected state. 121 -|X1.18-X1.20|LASER READY; LASER BUSY; LASER END|Use the transition order to distinguish a missing ready condition, a cycle that never started, or a cycle that did not complete normally. 122 -|X1.21-X1.24|Inputs 4 and 5; Outputs 4 and 5|Their assigned use depends on the delivered integration. Check the approved electrical documentation before interpreting them. 123 -|X1.25|GND for outputs|Active outputs supply 24 V and are evaluated against this output ground. The documented maximum output current is 250 mA. 124 - 125 - 126 - 127 -== Expected Diagnostic Sequence == 128 - 129 -1. Verify both emergency-stop channels and the required acknowledgement. 130 -1. Verify both shutter channels, the guard condition, and shutter acknowledgement. 131 -1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY. 132 -1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence. 133 -1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration. 134 - 135 -(% class="box warningmessage" %) 136 -((( 137 -**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine. 138 -))) 139 - 140 -= X2 Axis Interface = 141 - 142 -X2 is the 25-pin Sub-D axis interface. The manual groups direction and step outputs for X, Y, Z, and R with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energised probing guide.
- 1788773598823-721.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -146.5 KB - Content
- 1788775595167-399.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -45.5 KB - Content
- 1788775764610-963.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.3 KB - Content
- 1788776328447-524.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -45.6 KB - Content
- 1788776541211-163.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.8 KB - Content