Changes for page Troubleshooting
Last modified by jadomatis on 2026/09/07 13:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -130,6 +130,86 @@ 130 130 1. Verify both shutter channels, the guard condition, and shutter acknowledgement. 131 131 1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY. 132 132 1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence. 133 -1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration. **Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine.133 +1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration. 134 134 135 +(% class="box warningmessage" %) 136 +((( 137 +**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine. 138 +))) 139 + 140 + 141 + 142 += X2 Axis Interface = 143 + 144 +X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide. 145 + 146 +(% class="table-condensed table-striped" style="width:604px" %) 147 +|=(% style="width: 92px;" %)Pin|=(% style="width: 160px;" %)Direction|=(% style="width: 350px;" %)Description 148 +|(% style="width:92px" %)1|(% style="width:160px" %)Output|(% style="width:350px" %)Direction X 149 +|(% style="width:92px" %)2|(% style="width:160px" %)Output|(% style="width:350px" %)Step X 150 +|(% style="width:92px" %)3|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Y 151 +|(% style="width:92px" %)4|(% style="width:160px" %)Output|(% style="width:350px" %)Step Y 152 +|(% style="width:92px" %)5|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Z 153 +|(% style="width:92px" %)6|(% style="width:160px" %)Output|(% style="width:350px" %)Step Z 154 +|(% style="width:92px" %)7|(% style="width:160px" %)Output|(% style="width:350px" %)Direction R 155 +|(% style="width:92px" %)8|(% style="width:160px" %)Output|(% style="width:350px" %)Step R 156 +|(% style="width:92px" %)9|(% style="width:160px" %)Output|(% style="width:350px" %)Zero X 157 +|(% style="width:92px" %)10|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 158 +|(% style="width:92px" %)11|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Y 159 +|(% style="width:92px" %)12|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 160 +|(% style="width:92px" %)13|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Z 161 +|(% style="width:92px" %)14|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 162 +|(% style="width:92px" %)15|(% style="width:160px" %)Input|(% style="width:350px" %)Zero R 163 +|(% style="width:92px" %)16|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 164 +|(% style="width:92px" %)17|(% style="width:160px" %)Output|(% style="width:350px" %)GND 165 +|(% style="width:92px" %)18|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 166 +|(% style="width:92px" %)19|(% style="width:160px" %)Output|(% style="width:350px" %)+5V supply 167 +|(% style="width:92px" %)20|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 168 +|(% style="width:92px" %)21|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 169 +|(% style="width:92px" %)22|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 170 +|(% style="width:92px" %)23|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 171 +|(% style="width:92px" %)24|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 172 +|(% style="width:92px" %)25|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 173 + 174 + 175 + 176 += Diagnosing an X2 Axis Fault = 177 + 178 +(% class="box errormessage" %) 179 +((( 180 +**Before commanding movement: **Confirm that the area is clear, the workpiece and fixture are secure, the permitted travel is known, and the host machine is in its approved setup or service state. Stop immediately if movement is unexpected or mechanically obstructed. 181 +))) 182 + 183 +(% class="table-condensed table-striped" style="width:901px" %) 184 +|**Axis**|(% style="width:242px" %)**Direction output**|(% style="width:227px" %)**Step output**|(% style="width:278px" %)**Zero/reference signal** 185 +|X|(% style="width:242px" %)X2.1|(% style="width:227px" %)X2.2|(% style="width:278px" %)X2.9 186 +|Y|(% style="width:242px" %)X2.3|(% style="width:227px" %)X2.4|(% style="width:278px" %)X2.11 187 +|Z|(% style="width:242px" %)X2.5|(% style="width:227px" %)X2.6|(% style="width:278px" %)X2.13 188 +|R|(% style="width:242px" %)X2.7|(% style="width:227px" %)X2.8|(% style="width:278px" %)X2.15 189 + 190 + 191 + 192 +== Use the Signal Groups to Localise the Fault == 193 + 194 +* No commanded movement: identify the relevant direction/step pair - X2 pins 1-2 for X, 3-4 for Y, 5-6 for Z, or 7-8 for R - then check the approved axis configuration and host mechanics. 195 +* Axis will not reference: inspect the corresponding zero signal - X2.9 for X, X2.11 for Y, X2.13 for Z, or X2.15 for R - using the approved service procedure. 196 +* Unexpected direction, travel, repeated reference failure, or mechanical obstruction: stop movement and isolate the system. Do not continue jogging the axis to overcome the condition. 197 + 198 +(% class="box warningmessage" %) 199 +((( 200 + **Additional X2 pins: ** X2.17 is GND and X2.19 is the +5 V supply; the remaining listed pins are not connected. Voltage checks, connector work, and changes to axis wiring or configuration are service tasks for authorized personnel. 201 +))) 202 + 203 + 204 + 205 += Operator Checkpoints on the Laser Rack = 206 + 207 + 208 +[[image:1788778838681-766.png]] 209 + 210 + 211 +* Check the rear main switch, front laser key switch, status indicator, and approved host/AnyMarker connection. 212 +* Keep the cooling vents unobstructed. Stop operation if airflow is restricted, heat accumulates, or an abnormal smell or sound is present. 213 +* Visually inspect accessible cables and connectors without opening covers or disturbing the validated wiring. Isolate and escalate damage, looseness, overheating, or contamination. 214 + 135 135
- 1788778758156-557.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +535.6 KB - Content
- 1788778838681-766.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +216.4 KB - Content