Änderungen von Dokument Troubleshooting
Zuletzt geändert von jadomatis am 2026/09/07 13:51
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -105,31 +105,5 @@ 105 105 106 106 [[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]] 107 107 108 -(% class="box warningmessage" %) 109 -((( 110 -**Diagnostic meaning: **If either emergency-stop or shutter channel is open, inconsistent, or not acknowledged, LASER READY may remain absent. Never bridge a channel to prove this diagnosis; use the host safety-module indications and approved electrical test procedure. 111 -))) 112 112 113 - 114 -= X1 Production and Status I/O = 115 - 116 -After the safety circuits are valid, use the documented X1 command and status sequence to localise a control fault. Record which state is missing or which output changes first. 117 - 118 -|**Pin group**|**Documented function**|**Diagnostic use** 119 -|X1.13-X1.15|+24 V input supply; External START; External STOP|If START has no effect, confirm LASER READY before checking the host command. An active STOP or missing start condition can stop a cycle. 120 -|X1.16-X1.17|Emergency-stop status; SHUTTER status|These show whether the safety chain and shutter permission have reached the expected state. 121 -|X1.18-X1.20|LASER READY; LASER BUSY; LASER END|Use the transition order to distinguish a missing ready condition, a cycle that never started, or a cycle that did not complete normally. 122 -|X1.21-X1.24|Inputs 4 and 5; Outputs 4 and 5|Their assigned use depends on the delivered integration. Check the approved electrical documentation before interpreting them. 123 -|X1.25|GND for outputs|Active outputs supply 24 V and are evaluated against this output ground. The documented maximum output current is 250 mA. 124 - 125 - 126 - 127 -== Expected Diagnostic Sequence == 128 - 129 -1. Verify both emergency-stop channels and the required acknowledgement. 130 -1. Verify both shutter channels, the guard condition, and shutter acknowledgement. 131 -1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY. 132 -1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence. 133 -1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration.**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine. 134 - 135 135