Changes for page Troubleshooting

Last modified by jadomatis on 2026/09/07 13:51

From version 6.3
edited by jadomatis
on 2026/09/07 12:31
Change comment: There is no comment for this version
To version 8.2
edited by jadomatis
on 2026/09/07 13:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -110,4 +110,104 @@
110 110  **Diagnostic meaning: **If either emergency-stop or shutter channel is open, inconsistent, or not acknowledged, LASER READY may remain absent. Never bridge a channel to prove this diagnosis; use the host safety-module indications and approved electrical test procedure.
111 111  )))
112 112  
113 +
114 += X1 Production and Status I/O =
115 +
116 +After the safety circuits are valid, use the documented X1 command and status sequence to localise a control fault. Record which state is missing or which output changes first.
117 +
118 +|**Pin group**|**Documented function**|**Diagnostic use**
119 +|X1.13-X1.15|+24 V input supply; External START; External STOP|If START has no effect, confirm LASER READY before checking the host command. An active STOP or missing start condition can stop a cycle.
120 +|X1.16-X1.17|Emergency-stop status; SHUTTER status|These show whether the safety chain and shutter permission have reached the expected state.
121 +|X1.18-X1.20|LASER READY; LASER BUSY; LASER END|Use the transition order to distinguish a missing ready condition, a cycle that never started, or a cycle that did not complete normally.
122 +|X1.21-X1.24|Inputs 4 and 5; Outputs 4 and 5|Their assigned use depends on the delivered integration. Check the approved electrical documentation before interpreting them.
123 +|X1.25|GND for outputs|Active outputs supply 24 V and are evaluated against this output ground. The documented maximum output current is 250 mA.
124 +
125 +
126 +
127 +== Expected Diagnostic Sequence ==
128 +
129 +1. Verify both emergency-stop channels and the required acknowledgement.
130 +1. Verify both shutter channels, the guard condition, and shutter acknowledgement.
131 +1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY.
132 +1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence.
133 +1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration.
134 +
135 +(% class="box warningmessage" %)
136 +(((
137 +**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine.
138 +)))
139 +
140 +
141 +
142 += X2 Axis Interface =
143 +
144 +X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide.
145 +
146 +(% class="table-condensed table-striped" style="width:604px" %)
147 +|=(% style="width: 92px;" %)Pin|=(% style="width: 160px;" %)Direction|=(% style="width: 350px;" %)Description
148 +|(% style="width:92px" %)1|(% style="width:160px" %)Output|(% style="width:350px" %)Direction X
149 +|(% style="width:92px" %)2|(% style="width:160px" %)Output|(% style="width:350px" %)Step X
150 +|(% style="width:92px" %)3|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Y
151 +|(% style="width:92px" %)4|(% style="width:160px" %)Output|(% style="width:350px" %)Step Y
152 +|(% style="width:92px" %)5|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Z
153 +|(% style="width:92px" %)6|(% style="width:160px" %)Output|(% style="width:350px" %)Step Z
154 +|(% style="width:92px" %)7|(% style="width:160px" %)Output|(% style="width:350px" %)Direction R
155 +|(% style="width:92px" %)8|(% style="width:160px" %)Output|(% style="width:350px" %)Step R
156 +|(% style="width:92px" %)9|(% style="width:160px" %)Output|(% style="width:350px" %)Zero X
157 +|(% style="width:92px" %)10|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
158 +|(% style="width:92px" %)11|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Y
159 +|(% style="width:92px" %)12|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
160 +|(% style="width:92px" %)13|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Z
161 +|(% style="width:92px" %)14|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
162 +|(% style="width:92px" %)15|(% style="width:160px" %)Input|(% style="width:350px" %)Zero R
163 +|(% style="width:92px" %)16|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
164 +|(% style="width:92px" %)17|(% style="width:160px" %)Output|(% style="width:350px" %)GND
165 +|(% style="width:92px" %)18|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
166 +|(% style="width:92px" %)19|(% style="width:160px" %)Output|(% style="width:350px" %)+5V supply
167 +|(% style="width:92px" %)20|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
168 +|(% style="width:92px" %)21|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
169 +|(% style="width:92px" %)22|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
170 +|(% style="width:92px" %)23|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
171 +|(% style="width:92px" %)24|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
172 +|(% style="width:92px" %)25|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
173 +
174 +
175 +
176 += Diagnosing an X2 Axis Fault =
177 +
178 +(% class="box errormessage" %)
179 +(((
180 +**Before commanding movement: **Confirm that the area is clear, the workpiece and fixture are secure, the permitted travel is known, and the host machine is in its approved setup or service state. Stop immediately if movement is unexpected or mechanically obstructed.
181 +)))
182 +
183 +(% class="table-condensed table-striped" style="width:901px" %)
184 +|**Axis**|(% style="width:242px" %)**Direction output**|(% style="width:227px" %)**Step output**|(% style="width:278px" %)**Zero/reference signal**
185 +|X|(% style="width:242px" %)X2.1|(% style="width:227px" %)X2.2|(% style="width:278px" %)X2.9
186 +|Y|(% style="width:242px" %)X2.3|(% style="width:227px" %)X2.4|(% style="width:278px" %)X2.11
187 +|Z|(% style="width:242px" %)X2.5|(% style="width:227px" %)X2.6|(% style="width:278px" %)X2.13
188 +|R|(% style="width:242px" %)X2.7|(% style="width:227px" %)X2.8|(% style="width:278px" %)X2.15
189 +
190 +
191 +
192 +== Use the Signal Groups to Localise the Fault ==
193 +
194 +* No commanded movement: identify the relevant direction/step pair - X2 pins 1-2 for X, 3-4 for Y, 5-6 for Z, or 7-8 for R - then check the approved axis configuration and host mechanics.
195 +* Axis will not reference: inspect the corresponding zero signal - X2.9 for X, X2.11 for Y, X2.13 for Z, or X2.15 for R - using the approved service procedure.
196 +* Unexpected direction, travel, repeated reference failure, or mechanical obstruction: stop movement and isolate the system. Do not continue jogging the axis to overcome the condition.
197 +
198 +(% class="box warningmessage" %)
199 +(((
200 + **Additional X2 pins: ** X2.17 is GND and X2.19 is the +5 V supply; the remaining listed pins are not connected. Voltage checks, connector work, and changes to axis wiring or configuration are service tasks for authorized personnel.
201 +)))
202 +
203 += Operator Checkpoints on the Laser Rack =
204 +
205 +[[image:1788778838681-766.png]]
206 +
207 +
208 +Check the rear main switch, front laser key switch, status indicator, and approved host/AnyMarker connection.
209 +
210 +* Keep the cooling vents unobstructed. Stop operation if airflow is restricted, heat accumulates, or an abnormal smell or sound is present.
211 +* Visually inspect accessible cables and connectors without opening covers or disturbing the validated wiring. Isolate and escalate damage, looseness, overheating, or contamination.
212 +
113 113  
1788778758156-557.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +535.6 KB
Content
1788778838681-766.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +216.4 KB
Content