Changes for page Troubleshooting
Last modified by jadomatis on 2026/09/07 13:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -110,4 +110,65 @@ 110 110 **Diagnostic meaning: **If either emergency-stop or shutter channel is open, inconsistent, or not acknowledged, LASER READY may remain absent. Never bridge a channel to prove this diagnosis; use the host safety-module indications and approved electrical test procedure. 111 111 ))) 112 112 113 + 114 += X1 Production and Status I/O = 115 + 116 +After the safety circuits are valid, use the documented X1 command and status sequence to localise a control fault. Record which state is missing or which output changes first. 117 + 118 +|**Pin group**|**Documented function**|**Diagnostic use** 119 +|X1.13-X1.15|+24 V input supply; External START; External STOP|If START has no effect, confirm LASER READY before checking the host command. An active STOP or missing start condition can stop a cycle. 120 +|X1.16-X1.17|Emergency-stop status; SHUTTER status|These show whether the safety chain and shutter permission have reached the expected state. 121 +|X1.18-X1.20|LASER READY; LASER BUSY; LASER END|Use the transition order to distinguish a missing ready condition, a cycle that never started, or a cycle that did not complete normally. 122 +|X1.21-X1.24|Inputs 4 and 5; Outputs 4 and 5|Their assigned use depends on the delivered integration. Check the approved electrical documentation before interpreting them. 123 +|X1.25|GND for outputs|Active outputs supply 24 V and are evaluated against this output ground. The documented maximum output current is 250 mA. 124 + 125 + 126 + 127 +== Expected Diagnostic Sequence == 128 + 129 +1. Verify both emergency-stop channels and the required acknowledgement. 130 +1. Verify both shutter channels, the guard condition, and shutter acknowledgement. 131 +1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY. 132 +1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence. 133 +1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration. 134 + 135 +(% class="box warningmessage" %) 136 +((( 137 +**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine. 138 +))) 139 + 140 + 141 + 142 += X2 Axis Interface = 143 + 144 +X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide. 145 + 146 +(% class="table-condensed table-striped" style="width:604px" %) 147 +|=(% style="width: 92px;" %)Pin|=(% style="width: 160px;" %)Direction|=(% style="width: 350px;" %)Description 148 +|(% style="width:92px" %)1|(% style="width:160px" %)Output|(% style="width:350px" %)Direction X 149 +|(% style="width:92px" %)2|(% style="width:160px" %)Output|(% style="width:350px" %)Step X 150 +|(% style="width:92px" %)3|(% style="width:160px" %)Output|(% style="width:350px" %)Direction 151 +|(% style="width:92px" %)4|(% style="width:160px" %)Output|(% style="width:350px" %)Step 152 +|(% style="width:92px" %)5|(% style="width:160px" %)Output|(% style="width:350px" %)Direction 153 +|(% style="width:92px" %)6|(% style="width:160px" %)Output|(% style="width:350px" %)Step 154 +|(% style="width:92px" %)7|(% style="width:160px" %)Output|(% style="width:350px" %)Direction 155 +|(% style="width:92px" %)8|(% style="width:160px" %)Output|(% style="width:350px" %)Step 156 +|(% style="width:92px" %)9|(% style="width:160px" %)Output|(% style="width:350px" %)Zero 157 +|(% style="width:92px" %)10|(% style="width:160px" %)-|(% style="width:350px" %) 158 +|(% style="width:92px" %)11|(% style="width:160px" %)Input|(% style="width:350px" %) 159 +|(% style="width:92px" %)12|(% style="width:160px" %)-|(% style="width:350px" %) 160 +|(% style="width:92px" %)13|(% style="width:160px" %)Input|(% style="width:350px" %) 161 +|(% style="width:92px" %)14|(% style="width:160px" %)-|(% style="width:350px" %) 162 +|(% style="width:92px" %)15|(% style="width:160px" %)Input|(% style="width:350px" %) 163 +|(% style="width:92px" %)16|(% style="width:160px" %)-|(% style="width:350px" %) 164 +|(% style="width:92px" %)17|(% style="width:160px" %)Output|(% style="width:350px" %) 165 +|(% style="width:92px" %)18|(% style="width:160px" %)-|(% style="width:350px" %) 166 +|(% style="width:92px" %)19|(% style="width:160px" %)Output|(% style="width:350px" %) 167 +|(% style="width:92px" %)20|(% style="width:160px" %)-|(% style="width:350px" %) 168 +|(% style="width:92px" %)21|(% style="width:160px" %)-|(% style="width:350px" %) 169 +|(% style="width:92px" %)22|(% style="width:160px" %)-|(% style="width:350px" %) 170 +|(% style="width:92px" %)23|(% style="width:160px" %)-|(% style="width:350px" %) 171 +|(% style="width:92px" %)24|(% style="width:160px" %)-|(% style="width:350px" %) 172 +|(% style="width:92px" %)25|(% style="width:160px" %)-|(% style="width:350px" %) 173 + 113 113