... ... @@ -87,23 +87,6 @@
87 87  
88 88  
89 89  Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
90 -\\
90 +\\[[image:1788775764610-963.png]]
91 91  
92 -[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]]
93 -
94 -
95 -= X1 Safety Interface - Shutter Circuit =
96 -
97 -The shutter connection also uses two external safety channels: circuit 1 at X1.7/X1.8 and circuit 2 at X1.9/X1.10. Opening the protective enclosure must interrupt the shutter circuit. A closed and validated shutter circuit permits active mode; it does not by itself command a marking cycle.
98 98  
99 -
100 -[[**Example: dual shutter safety circuits at X1.7-X1.10.**>>image:1788776328447-524.png]]
101 -
102 -
103 -Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task.
104 -\\
105 -
106 -[[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]]
107 -
108 -
109 -
1788776328447-524.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Size
... ... @@ -1,1 +1,0 @@
1 -45.6 KB
Content
1788776541211-163.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Size
... ... @@ -1,1 +1,0 @@
1 -14.8 KB
Content