... ... @@ -81,13 +81,13 @@
81 81  )))
82 82  
83 83  (% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling.
84 -\\
84 +
85 85  
86 86  [[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]]
87 87  
88 88  
89 -Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
90 -\\
89 +\\Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
90 +
91 91  
92 92  [[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]]
93 93  
... ... @@ -101,7 +101,7 @@
101 101  
102 102  
103 103  Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task.
104 -\\
104 +
105 105  
106 106  [[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]]
107 107  
... ... @@ -195,4 +195,47 @@
195 195  * Axis will not reference: inspect the corresponding zero signal - X2.9 for X, X2.11 for Y, X2.13 for Z, or X2.15 for R - using the approved service procedure.
196 196  * Unexpected direction, travel, repeated reference failure, or mechanical obstruction: stop movement and isolate the system. Do not continue jogging the axis to overcome the condition.
197 197  
198 +(% class="box warningmessage" %)
199 +(((
200 + **Additional X2 pins: ** X2.17 is GND and X2.19 is the +5 V supply; the remaining listed pins are not connected. Voltage checks, connector work, and changes to axis wiring or configuration are service tasks for authorized personnel.
201 +)))
202 +
203 +
204 +
205 += Operator Checkpoints on the Laser Rack =
206 +
207 +
208 +[[image:1788778838681-766.png]]
209 +
210 +
211 +* Check the rear main switch, front laser key switch, status indicator, and approved host/AnyMarker connection.
212 +* Keep the cooling vents unobstructed. Stop operation if airflow is restricted, heat accumulates, or an abnormal smell or sound is present.
213 +* Visually inspect accessible cables and connectors without opening covers or disturbing the validated wiring. Isolate and escalate damage, looseness, overheating, or contamination.
214 +
215 +
216 +
217 += Stop and Escalate =
218 +
219 +Stop troubleshooting, isolate the equipment, and contact authorised service personnel when:
220 +
221 +* a safety channel, shutter circuit, guard function, acknowledgement or emission warning cannot be verified;
222 +* the same fault returns after one approved reset, or LASER READY/BUSY/END behaves unpredictably;
223 +* internal electrical, optical, cooling, laser-source, controller, X1/X2 wiring, or mechanical-axis access is required;
224 +* an optic, cable, connector, enclosure, laser-protection window, fixture, or extraction component is damaged; or
225 +* the cause is uncertain or the corrective action is outside the person's training and authority.
226 +
227 +
228 +
229 += Information for Schilling Service =
230 +
231 +Provide the serial number and exact Auto-Light model, AnyMarker version and job name, all host and laser messages, recorded X1 states, the event sequence, recent changes, and safe photographs or screenshots.
232 +
233 +(% class="box infomessage" %)
234 +(((
235 +**Schilling Service Centre**
236 +**+49 (07461) 9472-16**  |  Monday-Friday, 08:00-16:30
237 +**service@schilling-marking.de**  |  **www.schilling-marking.de**
238 +In Grubenaecker 1, 78532 Tuttlingen, Germany  |  **Fax +49 (07461) 9472-20**
239 +)))
240 +
198 198  
1788778758156-557.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +535.6 KB
Inhalt
1788778838681-766.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +216.4 KB
Inhalt