... ... @@ -142,57 +142,3 @@
142 142  = X2 Axis Interface =
143 143  
144 144  X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide.
145 -
146 -(% class="table-condensed table-striped" style="width:604px" %)
147 -|=(% style="width: 92px;" %)Pin|=(% style="width: 160px;" %)Direction|=(% style="width: 350px;" %)Description
148 -|(% style="width:92px" %)1|(% style="width:160px" %)Output|(% style="width:350px" %)Direction X
149 -|(% style="width:92px" %)2|(% style="width:160px" %)Output|(% style="width:350px" %)Step X
150 -|(% style="width:92px" %)3|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Y
151 -|(% style="width:92px" %)4|(% style="width:160px" %)Output|(% style="width:350px" %)Step Y
152 -|(% style="width:92px" %)5|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Z
153 -|(% style="width:92px" %)6|(% style="width:160px" %)Output|(% style="width:350px" %)Step Z
154 -|(% style="width:92px" %)7|(% style="width:160px" %)Output|(% style="width:350px" %)Direction R
155 -|(% style="width:92px" %)8|(% style="width:160px" %)Output|(% style="width:350px" %)Step R
156 -|(% style="width:92px" %)9|(% style="width:160px" %)Output|(% style="width:350px" %)Zero X
157 -|(% style="width:92px" %)10|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
158 -|(% style="width:92px" %)11|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Y
159 -|(% style="width:92px" %)12|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
160 -|(% style="width:92px" %)13|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Z
161 -|(% style="width:92px" %)14|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
162 -|(% style="width:92px" %)15|(% style="width:160px" %)Input|(% style="width:350px" %)Zero R
163 -|(% style="width:92px" %)16|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
164 -|(% style="width:92px" %)17|(% style="width:160px" %)Output|(% style="width:350px" %)GND
165 -|(% style="width:92px" %)18|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
166 -|(% style="width:92px" %)19|(% style="width:160px" %)Output|(% style="width:350px" %)+5V supply
167 -|(% style="width:92px" %)20|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
168 -|(% style="width:92px" %)21|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
169 -|(% style="width:92px" %)22|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
170 -|(% style="width:92px" %)23|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
171 -|(% style="width:92px" %)24|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
172 -|(% style="width:92px" %)25|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
173 -
174 -
175 -
176 -= Diagnosing an X2 Axis Fault =
177 -
178 -(% class="box errormessage" %)
179 -(((
180 -**Before commanding movement: **Confirm that the area is clear, the workpiece and fixture are secure, the permitted travel is known, and the host machine is in its approved setup or service state. Stop immediately if movement is unexpected or mechanically obstructed.
181 -)))
182 -
183 -(% class="table-condensed table-striped" style="width:901px" %)
184 -|**Axis**|(% style="width:242px" %)**Direction output**|(% style="width:227px" %)**Step output**|(% style="width:278px" %)**Zero/reference signal**
185 -|X|(% style="width:242px" %)X2.1|(% style="width:227px" %)X2.2|(% style="width:278px" %)X2.9
186 -|Y|(% style="width:242px" %)X2.3|(% style="width:227px" %)X2.4|(% style="width:278px" %)X2.11
187 -|Z|(% style="width:242px" %)X2.5|(% style="width:227px" %)X2.6|(% style="width:278px" %)X2.13
188 -|R|(% style="width:242px" %)X2.7|(% style="width:227px" %)X2.8|(% style="width:278px" %)X2.15
189 -
190 -
191 -
192 -== Use the Signal Groups to Localise the Fault ==
193 -
194 -* No commanded movement: identify the relevant direction/step pair - X2 pins 1-2 for X, 3-4 for Y, 5-6 for Z, or 7-8 for R - then check the approved axis configuration and host mechanics.
195 -* Axis will not reference: inspect the corresponding zero signal - X2.9 for X, X2.11 for Y, X2.13 for Z, or X2.15 for R - using the approved service procedure.
196 -* Unexpected direction, travel, repeated reference failure, or mechanical obstruction: stop movement and isolate the system. Do not continue jogging the axis to overcome the condition.
197 -
198 -