Changes for page Troubleshooting

Last modified by jadomatis on 2026/09/07 13:51

From version 6.14
edited by jadomatis
on 2026/09/07 13:00
Change comment: There is no comment for this version
To version 6.13
edited by jadomatis
on 2026/09/07 12:54
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -171,28 +171,4 @@
171 171  |(% style="width:92px" %)24|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
172 172  |(% style="width:92px" %)25|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
173 173  
174 -
175 -
176 -= Diagnosing an X2 Axis Fault =
177 -
178 -(% class="box errormessage" %)
179 -(((
180 -**Before commanding movement: **Confirm that the area is clear, the workpiece and fixture are secure, the permitted travel is known, and the host machine is in its approved setup or service state. Stop immediately if movement is unexpected or mechanically obstructed.
181 -)))
182 -
183 -(% class="table-condensed table-striped" style="width:901px" %)
184 -|**Axis**|(% style="width:242px" %)**Direction output**|(% style="width:227px" %)**Step output**|(% style="width:278px" %)**Zero/reference signal**
185 -|X|(% style="width:242px" %)X2.1|(% style="width:227px" %)X2.2|(% style="width:278px" %)X2.9
186 -|Y|(% style="width:242px" %)X2.3|(% style="width:227px" %)X2.4|(% style="width:278px" %)X2.11
187 -|Z|(% style="width:242px" %)X2.5|(% style="width:227px" %)X2.6|(% style="width:278px" %)X2.13
188 -|R|(% style="width:242px" %)X2.7|(% style="width:227px" %)X2.8|(% style="width:278px" %)X2.15
189 -
190 -
191 -
192 -== Use the Signal Groups to Localise the Fault ==
193 -
194 -* No commanded movement: identify the relevant direction/step pair - X2 pins 1-2 for X, 3-4 for Y, 5-6 for Z, or 7-8 for R - then check the approved axis configuration and host mechanics.
195 -* Axis will not reference: inspect the corresponding zero signal - X2.9 for X, X2.11 for Y, X2.13 for Z, or X2.15 for R - using the approved service procedure.
196 -* Unexpected direction, travel, repeated reference failure, or mechanical obstruction: stop movement and isolate the system. Do not continue jogging the axis to overcome the condition.
197 -
198 198