110 110  **Diagnostic meaning: **If either emergency-stop or shutter channel is open, inconsistent, or not acknowledged, LASER READY may remain absent. Never bridge a channel to prove this diagnosis; use the host safety-module indications and approved electrical test procedure.
111 111  )))
112 112  
113 -
114 -= X1 Production and Status I/O =
115 -
116 -After the safety circuits are valid, use the documented X1 command and status sequence to localise a control fault. Record which state is missing or which output changes first.
117 -
118 -|**Pin group**|**Documented function**|**Diagnostic use**
119 -|X1.13-X1.15|+24 V input supply; External START; External STOP|If START has no effect, confirm LASER READY before checking the host command. An active STOP or missing start condition can stop a cycle.
120 -|X1.16-X1.17|Emergency-stop status; SHUTTER status|These show whether the safety chain and shutter permission have reached the expected state.
121 -|X1.18-X1.20|LASER READY; LASER BUSY; LASER END|Use the transition order to distinguish a missing ready condition, a cycle that never started, or a cycle that did not complete normally.
122 -|X1.21-X1.24|Inputs 4 and 5; Outputs 4 and 5|Their assigned use depends on the delivered integration. Check the approved electrical documentation before interpreting them.
123 -|X1.25|GND for outputs|Active outputs supply 24 V and are evaluated against this output ground. The documented maximum output current is 250 mA.
124 -
125 -
126 -
127 -== Expected Diagnostic Sequence ==
128 -
129 -1. Verify both emergency-stop channels and the required acknowledgement.
130 -1. Verify both shutter channels, the guard condition, and shutter acknowledgement.
131 -1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY.
132 -1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence.
133 -1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration.
134 -
135 -(% class="box warningmessage" %)
136 -(((
137 -**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine.
138 -)))
139 -
140 -
141 -
142 -= X2 Axis Interface =
143 -
144 -X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide.
145 -
146 -(% class="table-condensed table-striped" style="width:604px" %)
147 -|=(% style="width: 92px;" %)Pin|=(% style="width: 160px;" %)Direction|=(% style="width: 350px;" %)Description
148 -|(% style="width:92px" %)1|(% style="width:160px" %)Output|(% style="width:350px" %)Direction X
149 -|(% style="width:92px" %)2|(% style="width:160px" %)Output|(% style="width:350px" %)Step X
150 -|(% style="width:92px" %)3|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Y
151 -|(% style="width:92px" %)4|(% style="width:160px" %)Output|(% style="width:350px" %)Step Y
152 -|(% style="width:92px" %)5|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Z
153 -|(% style="width:92px" %)6|(% style="width:160px" %)Output|(% style="width:350px" %)Step Z
154 -|(% style="width:92px" %)7|(% style="width:160px" %)Output|(% style="width:350px" %)Direction R
155 -|(% style="width:92px" %)8|(% style="width:160px" %)Output|(% style="width:350px" %)Step R
156 -|(% style="width:92px" %)9|(% style="width:160px" %)Output|(% style="width:350px" %)Zero X
157 -|(% style="width:92px" %)10|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
158 -|(% style="width:92px" %)11|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Y
159 -|(% style="width:92px" %)12|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
160 -|(% style="width:92px" %)13|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Z
161 -|(% style="width:92px" %)14|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
162 -|(% style="width:92px" %)15|(% style="width:160px" %)Input|(% style="width:350px" %)Zero R
163 -|(% style="width:92px" %)16|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
164 -|(% style="width:92px" %)17|(% style="width:160px" %)Output|(% style="width:350px" %)GND
165 -|(% style="width:92px" %)18|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
166 -|(% style="width:92px" %)19|(% style="width:160px" %)Output|(% style="width:350px" %)+5V supply
167 -|(% style="width:92px" %)20|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
168 -|(% style="width:92px" %)21|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
169 -|(% style="width:92px" %)22|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
170 -|(% style="width:92px" %)23|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
171 -|(% style="width:92px" %)24|(% style="width:160px" %)-|(% style="width:350px" %)Not connected
172 -|(% style="width:92px" %)25|(% style="width:160px" %)-|(% style="width:350px" %)Not connected