Changes for page Troubleshooting
Last modified by jadomatis on 2026/09/07 13:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -83,92 +83,4 @@ 83 83 (% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling. 84 84 \\ 85 85 86 -[[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]] 87 - 88 - 89 -Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition. 90 -\\ 91 - 92 -[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]] 93 - 94 - 95 -= X1 Safety Interface - Shutter Circuit = 96 - 97 -The shutter connection also uses two external safety channels: circuit 1 at X1.7/X1.8 and circuit 2 at X1.9/X1.10. Opening the protective enclosure must interrupt the shutter circuit. A closed and validated shutter circuit permits active mode; it does not by itself command a marking cycle. 98 - 99 - 100 -[[**Example: dual shutter safety circuits at X1.7-X1.10.**>>image:1788776328447-524.png]] 101 - 102 - 103 -Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task. 104 -\\ 105 - 106 -[[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]] 107 - 108 -(% class="box warningmessage" %) 109 -((( 110 -**Diagnostic meaning: **If either emergency-stop or shutter channel is open, inconsistent, or not acknowledged, LASER READY may remain absent. Never bridge a channel to prove this diagnosis; use the host safety-module indications and approved electrical test procedure. 111 -))) 112 - 113 - 114 -= X1 Production and Status I/O = 115 - 116 -After the safety circuits are valid, use the documented X1 command and status sequence to localise a control fault. Record which state is missing or which output changes first. 117 - 118 -|**Pin group**|**Documented function**|**Diagnostic use** 119 -|X1.13-X1.15|+24 V input supply; External START; External STOP|If START has no effect, confirm LASER READY before checking the host command. An active STOP or missing start condition can stop a cycle. 120 -|X1.16-X1.17|Emergency-stop status; SHUTTER status|These show whether the safety chain and shutter permission have reached the expected state. 121 -|X1.18-X1.20|LASER READY; LASER BUSY; LASER END|Use the transition order to distinguish a missing ready condition, a cycle that never started, or a cycle that did not complete normally. 122 -|X1.21-X1.24|Inputs 4 and 5; Outputs 4 and 5|Their assigned use depends on the delivered integration. Check the approved electrical documentation before interpreting them. 123 -|X1.25|GND for outputs|Active outputs supply 24 V and are evaluated against this output ground. The documented maximum output current is 250 mA. 124 - 125 - 126 - 127 -== Expected Diagnostic Sequence == 128 - 129 -1. Verify both emergency-stop channels and the required acknowledgement. 130 -1. Verify both shutter channels, the guard condition, and shutter acknowledgement. 131 -1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY. 132 -1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence. 133 -1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration. 134 - 135 -(% class="box warningmessage" %) 136 -((( 137 -**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine. 138 -))) 139 - 140 - 141 - 142 -= X2 Axis Interface = 143 - 144 -X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide. 145 - 146 -(% class="table-condensed table-striped" style="width:604px" %) 147 -|=(% style="width: 92px;" %)Pin|=(% style="width: 160px;" %)Direction|=(% style="width: 350px;" %)Description 148 -|(% style="width:92px" %)1|(% style="width:160px" %)Output|(% style="width:350px" %) 149 -|(% style="width:92px" %)2|(% style="width:160px" %)Output|(% style="width:350px" %) 150 -|(% style="width:92px" %)3|(% style="width:160px" %)Output|(% style="width:350px" %) 151 -|(% style="width:92px" %)4|(% style="width:160px" %)Output|(% style="width:350px" %) 152 -|(% style="width:92px" %)5|(% style="width:160px" %)Output|(% style="width:350px" %) 153 -|(% style="width:92px" %)6|(% style="width:160px" %)Output|(% style="width:350px" %) 154 -|(% style="width:92px" %)7|(% style="width:160px" %)Output|(% style="width:350px" %) 155 -|(% style="width:92px" %)8|(% style="width:160px" %)Output|(% style="width:350px" %) 156 -|(% style="width:92px" %)9|(% style="width:160px" %)Output|(% style="width:350px" %) 157 -|(% style="width:92px" %)10|(% style="width:160px" %)-|(% style="width:350px" %) 158 -|(% style="width:92px" %)11|(% style="width:160px" %)Input|(% style="width:350px" %) 159 -|(% style="width:92px" %)12|(% style="width:160px" %)-|(% style="width:350px" %) 160 -|(% style="width:92px" %)13|(% style="width:160px" %)Input|(% style="width:350px" %) 161 -|(% style="width:92px" %)14|(% style="width:160px" %)-|(% style="width:350px" %) 162 -|(% style="width:92px" %)15|(% style="width:160px" %)Input|(% style="width:350px" %) 163 -|(% style="width:92px" %)16|(% style="width:160px" %)-|(% style="width:350px" %) 164 -|(% style="width:92px" %)17|(% style="width:160px" %)Output|(% style="width:350px" %) 165 -|(% style="width:92px" %)18|(% style="width:160px" %)-|(% style="width:350px" %) 166 -|(% style="width:92px" %)19|(% style="width:160px" %)Output|(% style="width:350px" %) 167 -|(% style="width:92px" %)20|(% style="width:160px" %)-|(% style="width:350px" %) 168 -|(% style="width:92px" %)21|(% style="width:160px" %)-|(% style="width:350px" %) 169 -|(% style="width:92px" %)22|(% style="width:160px" %)-|(% style="width:350px" %) 170 -|(% style="width:92px" %)23|(% style="width:160px" %)-|(% style="width:350px" %) 171 -|(% style="width:92px" %)24|(% style="width:160px" %)-|(% style="width:350px" %) 172 -|(% style="width:92px" %)25|(% style="width:160px" %)-|(% style="width:350px" %) 173 - 174 - 86 +[[Example: dual emergency-stop safety circuits at X1.1-X1.4.>>image:1788775595167-399.png]]
- 1788775764610-963.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.3 KB - Content
- 1788776328447-524.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -45.6 KB - Content
- 1788776541211-163.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.8 KB - Content