... ... @@ -95,5 +95,41 @@ 95 95 = X1 Safety Interface - Shutter Circuit = 96 96 97 97 The shutter connection also uses two external safety channels: circuit 1 at X1.7/X1.8 and circuit 2 at X1.9/X1.10. Opening the protective enclosure must interrupt the shutter circuit. A closed and validated shutter circuit permits active mode; it does not by itself command a marking cycle. 98 + 98 98 100 +[[**Example: dual shutter safety circuits at X1.7-X1.10.**>>image:1788776328447-524.png]] 101 + 102 + 103 +Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task. 104 +\\ 105 + 106 +[[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]] 107 + 108 +(% class="box warningmessage" %) 109 +((( 110 +**Diagnostic meaning: **If either emergency-stop or shutter channel is open, inconsistent, or not acknowledged, LASER READY may remain absent. Never bridge a channel to prove this diagnosis; use the host safety-module indications and approved electrical test procedure. 111 +))) 112 + 113 + 114 += X1 Production and Status I/O = 115 + 116 +After the safety circuits are valid, use the documented X1 command and status sequence to localise a control fault. Record which state is missing or which output changes first. 117 + 118 +|**Pin group**|**Documented function**|**Diagnostic use** 119 +|X1.13-X1.15|+24 V input supply; External START; External STOP|If START has no effect, confirm LASER READY before checking the host command. An active STOP or missing start condition can stop a cycle. 120 +|X1.16-X1.17|Emergency-stop status; SHUTTER status|These show whether the safety chain and shutter permission have reached the expected state. 121 +|X1.18-X1.20|LASER READY; LASER BUSY; LASER END|Use the transition order to distinguish a missing ready condition, a cycle that never started, or a cycle that did not complete normally. 122 +|X1.21-X1.24|Inputs 4 and 5; Outputs 4 and 5|Their assigned use depends on the delivered integration. Check the approved electrical documentation before interpreting them. 123 +|X1.25|GND for outputs|Active outputs supply 24 V and are evaluated against this output ground. The documented maximum output current is 250 mA. 124 + 125 + 126 + 127 +== Expected Diagnostic Sequence == 128 + 129 +1. Verify both emergency-stop channels and the required acknowledgement. 130 +1. Verify both shutter channels, the guard condition, and shutter acknowledgement. 131 +1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY. 132 +1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence. 133 +1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration.**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine. 134 + 99 99
- 1788776328447-524.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Größe
-
... ... @@ -1,0 +1,1 @@ 1 +45.6 KB - Inhalt
- 1788776541211-163.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Größe
-
... ... @@ -1,0 +1,1 @@ 1 +14.8 KB - Inhalt