... ... @@ -83,7 +83,4 @@ 83 83 (% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling. 84 84 \\ 85 85 86 -[[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]] 87 - 88 - 89 -Emergency-stop acknowledgement is provided at X1.5/X1.6. at every system restart and after every emergency-stop actuation. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition. 86 +[[Example: dual emergency-stop safety circuits at X1.1-X1.4.>>image:1788775595167-399.png]]
- 1788775764610-963.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Größe
-
... ... @@ -1,1 +1,0 @@ 1 -15.3 KB - Inhalt