Änderungen von Dokument Troubleshooting

Zuletzt geändert von jadomatis am 2026/09/07 13:51

Von Version 3.3
bearbeitet von jadomatis
am 2026/09/07 12:15
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 6.9
bearbeitet von jadomatis
am 2026/09/07 12:42
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -86,4 +86,89 @@
86 86  [[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]]
87 87  
88 88  
89 -Emergency-stop acknowledgement is provided at X1.5/X1.6. at every system restart and after every emergency-stop actuation. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
89 +Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
90 +\\
91 +
92 +[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]]
93 +
94 +
95 += X1 Safety Interface - Shutter Circuit =
96 +
97 +The shutter connection also uses two external safety channels: circuit 1 at X1.7/X1.8 and circuit 2 at X1.9/X1.10. Opening the protective enclosure must interrupt the shutter circuit. A closed and validated shutter circuit permits active mode; it does not by itself command a marking cycle.
98 +
99 +
100 +[[**Example: dual shutter safety circuits at X1.7-X1.10.**>>image:1788776328447-524.png]]
101 +
102 +
103 +Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task.
104 +\\
105 +
106 +[[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]]
107 +
108 +(% class="box warningmessage" %)
109 +(((
110 +**Diagnostic meaning: **If either emergency-stop or shutter channel is open, inconsistent, or not acknowledged, LASER READY may remain absent. Never bridge a channel to prove this diagnosis; use the host safety-module indications and approved electrical test procedure.
111 +)))
112 +
113 +
114 += X1 Production and Status I/O =
115 +
116 +After the safety circuits are valid, use the documented X1 command and status sequence to localise a control fault. Record which state is missing or which output changes first.
117 +
118 +|**Pin group**|**Documented function**|**Diagnostic use**
119 +|X1.13-X1.15|+24 V input supply; External START; External STOP|If START has no effect, confirm LASER READY before checking the host command. An active STOP or missing start condition can stop a cycle.
120 +|X1.16-X1.17|Emergency-stop status; SHUTTER status|These show whether the safety chain and shutter permission have reached the expected state.
121 +|X1.18-X1.20|LASER READY; LASER BUSY; LASER END|Use the transition order to distinguish a missing ready condition, a cycle that never started, or a cycle that did not complete normally.
122 +|X1.21-X1.24|Inputs 4 and 5; Outputs 4 and 5|Their assigned use depends on the delivered integration. Check the approved electrical documentation before interpreting them.
123 +|X1.25|GND for outputs|Active outputs supply 24 V and are evaluated against this output ground. The documented maximum output current is 250 mA.
124 +
125 +
126 +
127 +== Expected Diagnostic Sequence ==
128 +
129 +1. Verify both emergency-stop channels and the required acknowledgement.
130 +1. Verify both shutter channels, the guard condition, and shutter acknowledgement.
131 +1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY.
132 +1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence.
133 +1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration.
134 +
135 +(% class="box warningmessage" %)
136 +(((
137 +**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine.
138 +)))
139 +
140 +
141 +
142 += X2 Axis Interface =
143 +
144 +X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide.
145 +
146 +(% class="table-condensed table-striped" style="width:604px" %)
147 +|=(% style="width: 92px;" %)Pin|=(% style="width: 160px;" %)Direction|=(% style="width: 350px;" %)Description
148 +|(% style="width:92px" %)1|(% style="width:160px" %)Output|(% style="width:350px" %)
149 +|(% style="width:92px" %)2|(% style="width:160px" %)Output|(% style="width:350px" %)
150 +|(% style="width:92px" %)3|(% style="width:160px" %)Output|(% style="width:350px" %)
151 +|(% style="width:92px" %)4|(% style="width:160px" %)Output|(% style="width:350px" %)
152 +|(% style="width:92px" %)5|(% style="width:160px" %)Output|(% style="width:350px" %)
153 +|(% style="width:92px" %)6|(% style="width:160px" %)Output|(% style="width:350px" %)
154 +|(% style="width:92px" %)7|(% style="width:160px" %)Output|(% style="width:350px" %)
155 +|(% style="width:92px" %)8|(% style="width:160px" %)Output|(% style="width:350px" %)
156 +|(% style="width:92px" %)9|(% style="width:160px" %)Output|(% style="width:350px" %)
157 +|(% style="width:92px" %)10|(% style="width:160px" %)-|(% style="width:350px" %)
158 +|(% style="width:92px" %)11|(% style="width:160px" %) |(% style="width:350px" %)
159 +|(% style="width:92px" %)12|(% style="width:160px" %)-|(% style="width:350px" %)
160 +|(% style="width:92px" %)13|(% style="width:160px" %) |(% style="width:350px" %)
161 +|(% style="width:92px" %)14|(% style="width:160px" %)-|(% style="width:350px" %)
162 +|(% style="width:92px" %)15|(% style="width:160px" %) |(% style="width:350px" %)
163 +|(% style="width:92px" %)16|(% style="width:160px" %)-|(% style="width:350px" %)
164 +|(% style="width:92px" %)17|(% style="width:160px" %)Output|(% style="width:350px" %)
165 +|(% style="width:92px" %)18|(% style="width:160px" %)-|(% style="width:350px" %)
166 +|(% style="width:92px" %)19|(% style="width:160px" %)Output|(% style="width:350px" %)
167 +|(% style="width:92px" %)20|(% style="width:160px" %)-|(% style="width:350px" %)
168 +|(% style="width:92px" %)21|(% style="width:160px" %)-|(% style="width:350px" %)
169 +|(% style="width:92px" %)22|(% style="width:160px" %)-|(% style="width:350px" %)
170 +|(% style="width:92px" %)23|(% style="width:160px" %)-|(% style="width:350px" %)
171 +|(% style="width:92px" %)24|(% style="width:160px" %)-|(% style="width:350px" %)
172 +|(% style="width:92px" %)25|(% style="width:160px" %)-|(% style="width:350px" %)
173 +
174 +
1788775764610-963.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +15.3 KB
Inhalt
1788776328447-524.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +45.6 KB
Inhalt
1788776541211-163.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +14.8 KB
Inhalt