... ... @@ -86,4 +86,7 @@
86 86  [[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]]
87 87  
88 88  
89 -Emergency-stop acknowledgement is provided at X1.5/X1.6. at every system restart and after every emergency-stop actuation. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
89 +Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.