Changes for page Troubleshooting
Last modified by jadomatis on 2026/09/07 13:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,69 +18,4 @@ 18 18 Correct only conditions covered by operator training. If the condition repeats, cannot be identified, or requires electrical, optical, or internal access, isolate the system and contact authorised service personnel. 19 19 20 20 21 -= Capture the Fault Before Resetting = 22 - 23 -(% class="table-condensed table-striped" style="width:1008px" %) 24 -|**Record**|(% style="width:764px" %)**Example** 25 -|System and job|(% style="width:764px" %)Auto-Light serial/model, AnyMarker version, job name, selected device and parameter set 26 -|What happened|(% style="width:764px" %)Would not become ready, stopped during marking, no mark, weak mark, axis fault, or communication loss 27 -|Signal state|(% style="width:764px" %)X1 emergency-stop, SHUTTER, LASER READY, LASER BUSY and LASER END; host guard and extraction states 28 -|Timing and evidence|(% style="width:764px" %)Time, last successful cycle, recent change, error text, and safe photographs or screenshots 29 - 30 - 31 - 32 -= Safety, Readiness, and Unexpected Stops = 33 - 34 -(% class="box infomessage" %) 35 -((( 36 -Functions and movements are permitted only while no fault is present and all required devices are ready. If a start condition is lost during operation, the integrated laser cell must stop. 37 -))) 38 - 39 -|**Symptom**|**Likely cause**|**Safe check or action** 40 -|System will not power on|Mains supply absent; rear main switch off; damaged cable; host supply or protection device open|Keep the system off. Check the approved supply, plug and cable externally. Do not open the rack. Escalate damaged wiring or repeated tripping. 41 -|No LASER READY|Emergency-stop or shutter chain not acknowledged; guard/access condition open; controller or laser fault; integration sequence incomplete|Read the host and AnyMarker messages. Verify the guard, dual emergency-stop and dual shutter states, then perform only the approved acknowledgement/reset sequence. 42 -|SHUTTER status missing|Protective enclosure open; shutter circuit interrupted; acknowledgement missing; safety module fault|Close and secure the host enclosure. Confirm the host safety module reports both shutter channels healthy. Do not bridge the circuit. 43 -|Start command has no effect|LASER READY absent; external START not reaching X1.14; job not ready; another start condition missing|Confirm LASER READY first. Check the host command sequence and AnyMarker job state. Pin-level testing is for qualified integration personnel only. 44 -|Laser stops during a cycle|A start condition was lost; external STOP at X1.15; guard, emergency-stop, shutter, extraction or controller fault|Leave the system stopped. Record which status changed first. Correct the initiating condition; do not repeatedly reset a recurring fault. 45 -|BUSY or END sequence abnormal|Job/control communication issue; external control timing; controller fault|Record LASER READY/BUSY/END timing and the AnyMarker message. Check the approved host sequence; escalate if the sequence differs from the validated integration. 46 - 47 - 48 - 49 -= No Mark, Weak Mark, or Long Cycle = 50 - 51 -|**Symptom**|**Possible cause**|**Safe check or action** 52 -|No visible mark|Safety permission absent; wrong job/device; unsuitable material; parameters produce no visible response|Confirm READY and SHUTTER status, the selected Auto-Light device and job, workpiece material, focus, and approved parameter assignment. Test only on an approved sample. 53 -|Mark is too weak|Incorrect Z value in the job or axis menu|Compare the commanded Z position with the validated setup. If an installed Z-axis has lost reference, stop and follow the approved axis-reference procedure before refocusing. 54 -|Mark is too weak|Focus is above or below the workpiece|Check the approved focal distance, fixture seating and workpiece height. Refocus before changing laser energy. 55 -|Mark is too weak|Objective contaminated or damaged|Stop and isolate the equipment. Inspect only as permitted by the maintenance procedure. Do not touch or clean optics unless trained and authorised. 56 -|Mark is too weak|Incorrect or unqualified parameters|Reload the validated recipe. If adjustment is authorised, change one controlled variable at a time and verify the result on an approved sample. 57 -|Marking takes too long|Low speed, insufficient effective energy, overly fine hatch spacing, too many passes, or unsuitable font|Compare the job with the released process. Use an approved plotter font where appropriate. Requalify any change that affects quality or cycle time. 58 -|Mark shifts or clips|Workpiece moved; fixture incorrect; pilot position, field, axis position or job origin changed|Stop emission. Secure the workpiece, verify the fixture and job origin with the pilot laser, and confirm axis position before another test. 59 - 60 -(% class="box warningmessage" %) 61 -((( 62 -**Do not tune blindly: **Power, speed, hatch spacing, focus, and font can be possible causes. Their combined effect depends on the laser source, optics, material, geometry and job. Use released parameters and requalify intentional changes. See the shared **[[Marking Methods article>>doc:Marking Methods.WebHome]]** for cross-system process guidance. 63 -))) 64 - 65 - 66 - 67 -= AnyMarker or Controller Communication = 68 - 69 -* Record the message before closing AnyMarker or restarting the controller. 70 -* Confirm the approved USB or Ethernet connection and the expected Auto-Light device selection without disconnecting cables during an active cycle. 71 -* If communication repeatedly drops, stop production and have the workstation, cable, controller and network path checked by authorised personnel. 72 - 73 -For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 74 - 75 - 76 -= X1 Safety Interface - Emergency-Stop Circuit = 77 - 78 -(% class="box errormessage" %) 79 -((( 80 -**Qualified personnel only: **The diagrams identify the documented interface connections; they are not instructions to probe or rewire an energized system. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require isolation and personnel authorized for the delivered integration. 81 -))) 82 - 83 -(% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling. 84 -\\ 85 - 86 -[[Example: dual emergency-stop safety circuits at X1.1-X1.4.>>image:1788775595167-399.png]] 21 +
- 1788773598823-721.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -146.5 KB - Content
- 1788775595167-399.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -45.5 KB - Content