Changes for page Troubleshooting
Last modified by jadomatis on 2026/09/07 13:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -80,4 +80,160 @@ 80 80 **Qualified personnel only: **The diagrams identify the documented interface connections; they are not instructions to probe or rewire an energized system. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require isolation and personnel authorized for the delivered integration. 81 81 ))) 82 82 83 -= (% style="font-size:14px" %) (%%) = 83 +(% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling. 84 +\\ 85 + 86 +[[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]] 87 + 88 + 89 +Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition. 90 +\\ 91 + 92 +[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]] 93 + 94 + 95 += X1 Safety Interface - Shutter Circuit = 96 + 97 +The shutter connection also uses two external safety channels: circuit 1 at X1.7/X1.8 and circuit 2 at X1.9/X1.10. Opening the protective enclosure must interrupt the shutter circuit. A closed and validated shutter circuit permits active mode; it does not by itself command a marking cycle. 98 + 99 + 100 +[[**Example: dual shutter safety circuits at X1.7-X1.10.**>>image:1788776328447-524.png]] 101 + 102 + 103 +Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task. 104 +\\ 105 + 106 +[[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]] 107 + 108 +(% class="box warningmessage" %) 109 +((( 110 +**Diagnostic meaning: **If either emergency-stop or shutter channel is open, inconsistent, or not acknowledged, LASER READY may remain absent. Never bridge a channel to prove this diagnosis; use the host safety-module indications and approved electrical test procedure. 111 +))) 112 + 113 + 114 += X1 Production and Status I/O = 115 + 116 +After the safety circuits are valid, use the documented X1 command and status sequence to localise a control fault. Record which state is missing or which output changes first. 117 + 118 +|**Pin group**|**Documented function**|**Diagnostic use** 119 +|X1.13-X1.15|+24 V input supply; External START; External STOP|If START has no effect, confirm LASER READY before checking the host command. An active STOP or missing start condition can stop a cycle. 120 +|X1.16-X1.17|Emergency-stop status; SHUTTER status|These show whether the safety chain and shutter permission have reached the expected state. 121 +|X1.18-X1.20|LASER READY; LASER BUSY; LASER END|Use the transition order to distinguish a missing ready condition, a cycle that never started, or a cycle that did not complete normally. 122 +|X1.21-X1.24|Inputs 4 and 5; Outputs 4 and 5|Their assigned use depends on the delivered integration. Check the approved electrical documentation before interpreting them. 123 +|X1.25|GND for outputs|Active outputs supply 24 V and are evaluated against this output ground. The documented maximum output current is 250 mA. 124 + 125 + 126 + 127 +== Expected Diagnostic Sequence == 128 + 129 +1. Verify both emergency-stop channels and the required acknowledgement. 130 +1. Verify both shutter channels, the guard condition, and shutter acknowledgement. 131 +1. Confirm Emergency-stop status and SHUTTER status before expecting LASER READY. 132 +1. With LASER READY present, check whether External START is received and whether LASER BUSY then LASER END follows the validated host sequence. 133 +1. If the sequence differs, record the states and stop. Do not change timing, wiring, or safety logic unless authorised for the integration. 134 + 135 +(% class="box warningmessage" %) 136 +((( 137 +**Status outputs are evidence, not permission to bypass: **A missing signal helps locate the fault but does not authorise forcing an input or output. Troubleshoot the host safety system, Auto-Light interface, and controller as the validated integrated machine. 138 +))) 139 + 140 + 141 + 142 += X2 Axis Interface = 143 + 144 +X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide. 145 + 146 +(% class="table-condensed table-striped" style="width:604px" %) 147 +|=(% style="width: 92px;" %)Pin|=(% style="width: 160px;" %)Direction|=(% style="width: 350px;" %)Description 148 +|(% style="width:92px" %)1|(% style="width:160px" %)Output|(% style="width:350px" %)Direction X 149 +|(% style="width:92px" %)2|(% style="width:160px" %)Output|(% style="width:350px" %)Step X 150 +|(% style="width:92px" %)3|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Y 151 +|(% style="width:92px" %)4|(% style="width:160px" %)Output|(% style="width:350px" %)Step Y 152 +|(% style="width:92px" %)5|(% style="width:160px" %)Output|(% style="width:350px" %)Direction Z 153 +|(% style="width:92px" %)6|(% style="width:160px" %)Output|(% style="width:350px" %)Step Z 154 +|(% style="width:92px" %)7|(% style="width:160px" %)Output|(% style="width:350px" %)Direction R 155 +|(% style="width:92px" %)8|(% style="width:160px" %)Output|(% style="width:350px" %)Step R 156 +|(% style="width:92px" %)9|(% style="width:160px" %)Output|(% style="width:350px" %)Zero X 157 +|(% style="width:92px" %)10|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 158 +|(% style="width:92px" %)11|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Y 159 +|(% style="width:92px" %)12|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 160 +|(% style="width:92px" %)13|(% style="width:160px" %)Input|(% style="width:350px" %)Zero Z 161 +|(% style="width:92px" %)14|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 162 +|(% style="width:92px" %)15|(% style="width:160px" %)Input|(% style="width:350px" %)Zero R 163 +|(% style="width:92px" %)16|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 164 +|(% style="width:92px" %)17|(% style="width:160px" %)Output|(% style="width:350px" %)GND 165 +|(% style="width:92px" %)18|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 166 +|(% style="width:92px" %)19|(% style="width:160px" %)Output|(% style="width:350px" %)+5V supply 167 +|(% style="width:92px" %)20|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 168 +|(% style="width:92px" %)21|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 169 +|(% style="width:92px" %)22|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 170 +|(% style="width:92px" %)23|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 171 +|(% style="width:92px" %)24|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 172 +|(% style="width:92px" %)25|(% style="width:160px" %)-|(% style="width:350px" %)Not connected 173 + 174 + 175 + 176 += Diagnosing an X2 Axis Fault = 177 + 178 +(% class="box errormessage" %) 179 +((( 180 +**Before commanding movement: **Confirm that the area is clear, the workpiece and fixture are secure, the permitted travel is known, and the host machine is in its approved setup or service state. Stop immediately if movement is unexpected or mechanically obstructed. 181 +))) 182 + 183 +(% class="table-condensed table-striped" style="width:901px" %) 184 +|**Axis**|(% style="width:242px" %)**Direction output**|(% style="width:227px" %)**Step output**|(% style="width:278px" %)**Zero/reference signal** 185 +|X|(% style="width:242px" %)X2.1|(% style="width:227px" %)X2.2|(% style="width:278px" %)X2.9 186 +|Y|(% style="width:242px" %)X2.3|(% style="width:227px" %)X2.4|(% style="width:278px" %)X2.11 187 +|Z|(% style="width:242px" %)X2.5|(% style="width:227px" %)X2.6|(% style="width:278px" %)X2.13 188 +|R|(% style="width:242px" %)X2.7|(% style="width:227px" %)X2.8|(% style="width:278px" %)X2.15 189 + 190 + 191 + 192 +== Use the Signal Groups to Localise the Fault == 193 + 194 +* No commanded movement: identify the relevant direction/step pair - X2 pins 1-2 for X, 3-4 for Y, 5-6 for Z, or 7-8 for R - then check the approved axis configuration and host mechanics. 195 +* Axis will not reference: inspect the corresponding zero signal - X2.9 for X, X2.11 for Y, X2.13 for Z, or X2.15 for R - using the approved service procedure. 196 +* Unexpected direction, travel, repeated reference failure, or mechanical obstruction: stop movement and isolate the system. Do not continue jogging the axis to overcome the condition. 197 + 198 +(% class="box warningmessage" %) 199 +((( 200 + **Additional X2 pins: ** X2.17 is GND and X2.19 is the +5 V supply; the remaining listed pins are not connected. Voltage checks, connector work, and changes to axis wiring or configuration are service tasks for authorized personnel. 201 +))) 202 + 203 + 204 + 205 += Operator Checkpoints on the Laser Rack = 206 + 207 + 208 +[[image:1788778838681-766.png]] 209 + 210 + 211 +* Check the rear main switch, front laser key switch, status indicator, and approved host/AnyMarker connection. 212 +* Keep the cooling vents unobstructed. Stop operation if airflow is restricted, heat accumulates, or an abnormal smell or sound is present. 213 +* Visually inspect accessible cables and connectors without opening covers or disturbing the validated wiring. Isolate and escalate damage, looseness, overheating, or contamination. 214 + 215 + 216 + 217 += Stop and Escalate = 218 + 219 +Stop troubleshooting, isolate the equipment, and contact authorised service personnel when: 220 + 221 +* a safety channel, shutter circuit, guard function, acknowledgement or emission warning cannot be verified; 222 +* the same fault returns after one approved reset, or LASER READY/BUSY/END behaves unpredictably; 223 +* internal electrical, optical, cooling, laser-source, controller, X1/X2 wiring, or mechanical-axis access is required; 224 +* an optic, cable, connector, enclosure, laser-protection window, fixture, or extraction component is damaged; or 225 +* the cause is uncertain or the corrective action is outside the person's training and authority. 226 + 227 + 228 + 229 += Information for Schilling Service = 230 + 231 +Provide the serial number and exact Auto-Light model, AnyMarker version and job name, all host and laser messages, recorded X1 states, the event sequence, recent changes, and safe photographs or screenshots. 232 + 233 +(% class="box infomessage" %) 234 +((( 235 +**Schilling Service Centre** 236 +**+49 (07461) 9472-16** | Monday-Friday, 08:00-16:30 237 +**service@schilling-marking.de** | **www.schilling-marking.de** 238 +In Grubenaecker 1, 78532 Tuttlingen, Germany | **Fax +49 (07461) 9472-20** 239 +)))
- 1788775595167-399.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +45.5 KB - Content
- 1788775764610-963.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.3 KB - Content
- 1788776328447-524.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +45.6 KB - Content
- 1788776541211-163.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.8 KB - Content
- 1788778758156-557.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +535.6 KB - Content
- 1788778838681-766.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +216.4 KB - Content