80 80  **Qualified personnel only: **The diagrams identify the documented interface connections; they are not instructions to probe or rewire an energized system. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require isolation and personnel authorized for the delivered integration.
81 81  )))
82 82  
83 -= (% style="font-size:14px" %) (%%) =
83 +(% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling.
84 +\\
85 +
86 +[[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]]
87 +
88 +
89 +Emergency-stop acknowledgement is provided at X1.5/X1.6. at every system restart and after every emergency-stop actuation. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.