Changes for page Troubleshooting

Last modified by jadomatis on 2026/09/07 13:51

From version 2.4
edited by jadomatis
on 2026/09/07 11:43
Change comment: There is no comment for this version
To version 6.2
edited by jadomatis
on 2026/09/07 12:30
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -73,21 +73,37 @@
73 73  For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**.
74 74  
75 75  
76 -= X1 and X2 Diagnostic Boundary =
76 += X1 Safety Interface - Emergency-Stop Circuit =
77 77  
78 78  (% class="box errormessage" %)
79 79  (((
80 -**Qualified personnel only: **The following signal map helps identify where a fault belongs. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require the system to be isolated and may be performed only by personnel authorised for the delivered integration.
80 +**Qualified personnel only: **The diagrams identify the documented interface connections; they are not instructions to probe or rewire an energized system. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require isolation and personnel authorized for the delivered integration.
81 81  )))
82 82  
83 -[[image:1788773598823-721.png]]
83 +(% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling.
84 +\\
84 84  
86 +[[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]]
85 85  
86 -|**Interface**|**Relevant signals**|**Diagnostic meaning**
87 -|X1 safety|Pins 1-4: dual emergency-stop circuits; 5-6: acknowledgement|Both channels and the approved acknowledgement must be valid before operation.
88 -|X1 shutter|Pins 7-10: dual shutter circuits; 11-12: acknowledgement|Opening the protective enclosure must interrupt the shutter circuit. Never bypass either channel.
89 -|X1 control|13: +24 V; 14: START; 15: STOP|Check the host command sequence only after the safety states are valid.
90 -|X1 status|16: E-stop; 17: SHUTTER; 18: READY; 19: BUSY; 20: END|Record which output is absent or changes first. Active outputs provide 24 V; maximum output current is 250 mA.
91 -|X2 axes|Direction/step for X, Y, Z, R; zero inputs|A motion or reference fault may belong to the host mechanics, axis wiring, limit/reference input, or configuration.
92 92  
89 +Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
90 +\\
91 +
92 +[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]]
93 +
94 +
95 += X1 Safety Interface - Shutter Circuit =
96 +
97 +The shutter connection also uses two external safety channels: circuit 1 at X1.7/X1.8 and circuit 2 at X1.9/X1.10. Opening the protective enclosure must interrupt the shutter circuit. A closed and validated shutter circuit permits active mode; it does not by itself command a marking cycle.
93 93  
99 +
100 +[[**Example: dual shutter safety circuits at X1.7-X1.10.**>>image:1788776328447-524.png]]
101 +
102 +
103 +Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task.
104 +\\
105 +
106 +[[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]]
107 +
108 +
109 +
1788775595167-399.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +45.5 KB
Content
1788775764610-963.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +15.3 KB
Content
1788776328447-524.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +45.6 KB
Content
1788776541211-163.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +14.8 KB
Content