Changes for page Troubleshooting
Last modified by jadomatis on 2026/09/07 13:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -73,21 +73,14 @@ 73 73 For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 74 74 75 75 76 -= X1 an dX2DiagnosticBoundary=76 += X1 Safety Interface - Emergency-Stop Circuit = 77 77 78 78 (% class="box errormessage" %) 79 79 ((( 80 -**Qualified personnel only: **The followingsignalmap helps identifywhere afault belongs. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work requirethe system to beisolatedandmay beperformed only by personnel authorised for the delivered integration.80 +**Qualified personnel only: **The diagrams identify the documented interface connections; they are not instructions to probe or rewire an energized system. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require isolation and personnel authorized for the delivered integration. 81 81 ))) 82 82 83 -[[image:1788773598823-721.png]] 83 +(% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling. 84 +\\ 84 84 85 - 86 -|**Interface**|**Relevant signals**|**Diagnostic meaning** 87 -|X1 safety|Pins 1-4: dual emergency-stop circuits; 5-6: acknowledgement|Both channels and the approved acknowledgement must be valid before operation. 88 -|X1 shutter|Pins 7-10: dual shutter circuits; 11-12: acknowledgement|Opening the protective enclosure must interrupt the shutter circuit. Never bypass either channel. 89 -|X1 control|13: +24 V; 14: START; 15: STOP|Check the host command sequence only after the safety states are valid. 90 -|X1 status|16: E-stop; 17: SHUTTER; 18: READY; 19: BUSY; 20: END|Record which output is absent or changes first. Active outputs provide 24 V; maximum output current is 250 mA. 91 -|X2 axes|Direction/step for X, Y, Z, R; zero inputs|A motion or reference fault may belong to the host mechanics, axis wiring, limit/reference input, or configuration. 92 - 93 - 86 +[[Example: dual emergency-stop safety circuits at X1.1-X1.4.>>image:1788775595167-399.png]]
- 1788775595167-399.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +45.5 KB - Content