Änderungen von Dokument Troubleshooting

Zuletzt geändert von jadomatis am 2026/09/07 13:51

Von Version 2.3
bearbeitet von jadomatis
am 2026/09/07 11:42
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 6.2
bearbeitet von jadomatis
am 2026/09/07 12:30
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -73,14 +73,37 @@
73 73  For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**.
74 74  
75 75  
76 -= X1 and X2 Diagnostic Boundary =
76 += X1 Safety Interface - Emergency-Stop Circuit =
77 77  
78 78  (% class="box errormessage" %)
79 79  (((
80 -**Qualified personnel only: **The following signal map helps identify where a fault belongs. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require the system to be isolated and may be performed only by personnel authorised for the delivered integration.
80 +**Qualified personnel only: **The diagrams identify the documented interface connections; they are not instructions to probe or rewire an energized system. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require isolation and personnel authorized for the delivered integration.
81 81  )))
82 82  
83 -[[image:1788773598823-721.png]]
83 +(% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling.
84 +\\
84 84  
86 +[[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]]
85 85  
88 +
89 +Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
90 +\\
91 +
92 +[[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]]
93 +
94 +
95 += X1 Safety Interface - Shutter Circuit =
96 +
97 +The shutter connection also uses two external safety channels: circuit 1 at X1.7/X1.8 and circuit 2 at X1.9/X1.10. Opening the protective enclosure must interrupt the shutter circuit. A closed and validated shutter circuit permits active mode; it does not by itself command a marking cycle.
86 86  
99 +
100 +[[**Example: dual shutter safety circuits at X1.7-X1.10.**>>image:1788776328447-524.png]]
101 +
102 +
103 +Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task.
104 +\\
105 +
106 +[[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]]
107 +
108 +
109 +
1788775595167-399.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +45.5 KB
Inhalt
1788775764610-963.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +15.3 KB
Inhalt
1788776328447-524.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +45.6 KB
Inhalt
1788776541211-163.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +14.8 KB
Inhalt