56 56  |Mark is too weak|Incorrect or unqualified parameters|Reload the validated recipe. If adjustment is authorised, change one controlled variable at a time and verify the result on an approved sample.
57 57  |Marking takes too long|Low speed, insufficient effective energy, overly fine hatch spacing, too many passes, or unsuitable font|Compare the job with the released process. Use an approved plotter font where appropriate. Requalify any change that affects quality or cycle time.
58 58  |Mark shifts or clips|Workpiece moved; fixture incorrect; pilot position, field, axis position or job origin changed|Stop emission. Secure the workpiece, verify the fixture and job origin with the pilot laser, and confirm axis position before another test.
59 -
60 -(% class="box warningmessage" %)
61 -(((
62 -**Do not tune blindly: **Power, speed, hatch spacing, focus, and font can be possible causes. Their combined effect depends on the laser source, optics, material, geometry and job. Use released parameters and requalify intentional changes. See the shared **[[Marking Methods article>>doc:Marking Methods.WebHome]]** for cross-system process guidance.
63 -)))
64 -
65 -
66 -
67 -= AnyMarker or Controller Communication =
68 -
69 -* Record the message before closing AnyMarker or restarting the controller.
70 -* Confirm the approved USB or Ethernet connection and the expected Auto-Light device selection without disconnecting cables during an active cycle.
71 -* If communication repeatedly drops, stop production and have the workstation, cable, controller and network path checked by authorised personnel.
72 -
73 -For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**.