Changes for page Troubleshooting
Last modified by jadomatis on 2026/09/07 13:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -62,4 +62,32 @@ 62 62 **Do not tune blindly: **Power, speed, hatch spacing, focus, and font can be possible causes. Their combined effect depends on the laser source, optics, material, geometry and job. Use released parameters and requalify intentional changes. See the shared **[[Marking Methods article>>doc:Marking Methods.WebHome]]** for cross-system process guidance. 63 63 ))) 64 64 65 + 66 + 67 += AnyMarker or Controller Communication = 68 + 69 +* Record the message before closing AnyMarker or restarting the controller. 70 +* Confirm the approved USB or Ethernet connection and the expected Auto-Light device selection without disconnecting cables during an active cycle. 71 +* If communication repeatedly drops, stop production and have the workstation, cable, controller and network path checked by authorised personnel. 72 + 73 +For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 74 + 75 + 76 += X1 and X2 Diagnostic Boundary = 77 + 78 +(% class="box errormessage" %) 79 +((( 80 +**Qualified personnel only: **The following signal map helps identify where a fault belongs. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require the system to be isolated and may be performed only by personnel authorised for the delivered integration. 81 +))) 82 + 83 +[[image:1788773598823-721.png]] 84 + 85 + 86 +|**Interface**|**Relevant signals**|**Diagnostic meaning** 87 +|X1 safety|Pins 1-4: dual emergency-stop circuits; 5-6: acknowledgement|Both channels and the approved acknowledgement must be valid before operation. 88 +|X1 shutter|Pins 7-10: dual shutter circuits; 11-12: acknowledgement|Opening the protective enclosure must interrupt the shutter circuit. Never bypass either channel. 89 +|X1 control|13: +24 V; 14: START; 15: STOP|Check the host command sequence only after the safety states are valid. 90 +|X1 status|16: E-stop; 17: SHUTTER; 18: READY; 19: BUSY; 20: END|Record which output is absent or changes first. Active outputs provide 24 V; maximum output current is 250 mA. 91 +|X2 axes|Direction/step for X, Y, Z, R; zero inputs|A motion or reference fault may belong to the host mechanics, axis wiring, limit/reference input, or configuration. 92 + 65 65
- 1788773598823-721.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +146.5 KB - Content