Changes for page Troubleshooting
Last modified by jadomatis on 2026/09/07 13:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -46,4 +46,13 @@ 46 46 47 47 48 48 49 - 49 += No Mark, Weak Mark, or Long Cycle = 50 + 51 +|**Symptom**|**Possible cause**|**Safe check or action** 52 +|No visible mark|Safety permission absent; wrong job/device; unsuitable material; parameters produce no visible response|Confirm READY and SHUTTER status, the selected Auto-Light device and job, workpiece material, focus, and approved parameter assignment. Test only on an approved sample. 53 +|Mark is too weak|Incorrect Z value in the job or axis menu|Compare the commanded Z position with the validated setup. If an installed Z-axis has lost reference, stop and follow the approved axis-reference procedure before refocusing. 54 +|Mark is too weak|Focus is above or below the workpiece|Check the approved focal distance, fixture seating and workpiece height. Refocus before changing laser energy. 55 +|Mark is too weak|Objective contaminated or damaged|Stop and isolate the equipment. Inspect only as permitted by the maintenance procedure. Do not touch or clean optics unless trained and authorised. 56 +|Mark is too weak|Incorrect or unqualified parameters|Reload the validated recipe. If adjustment is authorised, change one controlled variable at a time and verify the result on an approved sample. 57 +|Marking takes too long|Low speed, insufficient effective energy, overly fine hatch spacing, too many passes, or unsuitable font|Compare the job with the released process. Use an approved plotter font where appropriate. Requalify any change that affects quality or cycle time. 58 +|Mark shifts or clips|Workpiece moved; fixture incorrect; pilot position, field, axis position or job origin changed|Stop emission. Secure the workpiece, verify the fixture and job origin with the pilot laser, and confirm axis position before another test.