Änderungen von Dokument Troubleshooting
Zuletzt geändert von jadomatis am 2026/09/07 13:51
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -27,23 +27,4 @@ 27 27 |Signal state|(% style="width:764px" %)X1 emergency-stop, SHUTTER, LASER READY, LASER BUSY and LASER END; host guard and extraction states 28 28 |Timing and evidence|(% style="width:764px" %)Time, last successful cycle, recent change, error text, and safe photographs or screenshots 29 29 30 - 31 - 32 -= Safety, Readiness, and Unexpected Stops = 33 - 34 -(% class="box infomessage" %) 35 -((( 36 -Functions and movements are permitted only while no fault is present and all required devices are ready. If a start condition is lost during operation, the integrated laser cell must stop. 37 -))) 38 - 39 -|**Symptom**|**Likely cause**|**Safe check or action** 40 -|System will not power on|Mains supply absent; rear main switch off; damaged cable; host supply or protection device open|Keep the system off. Check the approved supply, plug and cable externally. Do not open the rack. Escalate damaged wiring or repeated tripping. 41 -|No LASER READY|Emergency-stop or shutter chain not acknowledged; guard/access condition open; controller or laser fault; integration sequence incomplete|Read the host and AnyMarker messages. Verify the guard, dual emergency-stop and dual shutter states, then perform only the approved acknowledgement/reset sequence. 42 -|SHUTTER status missing|Protective enclosure open; shutter circuit interrupted; acknowledgement missing; safety module fault|Close and secure the host enclosure. Confirm the host safety module reports both shutter channels healthy. Do not bridge the circuit. 43 -|Start command has no effect|LASER READY absent; external START not reaching X1.14; job not ready; another start condition missing|Confirm LASER READY first. Check the host command sequence and AnyMarker job state. Pin-level testing is for qualified integration personnel only. 44 -|Laser stops during a cycle|A start condition was lost; external STOP at X1.15; guard, emergency-stop, shutter, extraction or controller fault|Leave the system stopped. Record which status changed first. Correct the initiating condition; do not repeatedly reset a recurring fault. 45 -|BUSY or END sequence abnormal|Job/control communication issue; external control timing; controller fault|Record LASER READY/BUSY/END timing and the AnyMarker message. Check the approved host sequence; escalate if the sequence differs from the validated integration. 46 - 47 - 48 - 49 49