Änderungen von Dokument Troubleshooting

Zuletzt geändert von jadomatis am 2026/09/07 13:51

Von Version 1.5
bearbeitet von jadomatis
am 2026/09/07 11:24
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 2.4
bearbeitet von jadomatis
am 2026/09/07 11:43
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -46,4 +46,48 @@
46 46  
47 47  
48 48  
49 += No Mark, Weak Mark, or Long Cycle =
50 +
51 +|**Symptom**|**Possible cause**|**Safe check or action**
52 +|No visible mark|Safety permission absent; wrong job/device; unsuitable material; parameters produce no visible response|Confirm READY and SHUTTER status, the selected Auto-Light device and job, workpiece material, focus, and approved parameter assignment. Test only on an approved sample.
53 +|Mark is too weak|Incorrect Z value in the job or axis menu|Compare the commanded Z position with the validated setup. If an installed Z-axis has lost reference, stop and follow the approved axis-reference procedure before refocusing.
54 +|Mark is too weak|Focus is above or below the workpiece|Check the approved focal distance, fixture seating and workpiece height. Refocus before changing laser energy.
55 +|Mark is too weak|Objective contaminated or damaged|Stop and isolate the equipment. Inspect only as permitted by the maintenance procedure. Do not touch or clean optics unless trained and authorised.
56 +|Mark is too weak|Incorrect or unqualified parameters|Reload the validated recipe. If adjustment is authorised, change one controlled variable at a time and verify the result on an approved sample.
57 +|Marking takes too long|Low speed, insufficient effective energy, overly fine hatch spacing, too many passes, or unsuitable font|Compare the job with the released process. Use an approved plotter font where appropriate. Requalify any change that affects quality or cycle time.
58 +|Mark shifts or clips|Workpiece moved; fixture incorrect; pilot position, field, axis position or job origin changed|Stop emission. Secure the workpiece, verify the fixture and job origin with the pilot laser, and confirm axis position before another test.
59 +
60 +(% class="box warningmessage" %)
61 +(((
62 +**Do not tune blindly: **Power, speed, hatch spacing, focus, and font can be possible causes. Their combined effect depends on the laser source, optics, material, geometry and job. Use released parameters and requalify intentional changes. See the shared **[[Marking Methods article>>doc:Marking Methods.WebHome]]** for cross-system process guidance.
63 +)))
64 +
65 +
66 +
67 += AnyMarker or Controller Communication =
68 +
69 +* Record the message before closing AnyMarker or restarting the controller.
70 +* Confirm the approved USB or Ethernet connection and the expected Auto-Light device selection without disconnecting cables during an active cycle.
71 +* If communication repeatedly drops, stop production and have the workstation, cable, controller and network path checked by authorised personnel.
72 +
73 +For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**.
74 +
75 +
76 += X1 and X2 Diagnostic Boundary =
77 +
78 +(% class="box errormessage" %)
79 +(((
80 +**Qualified personnel only: **The following signal map helps identify where a fault belongs. Electrical measurement, connector removal, rewiring, safety-module work, and axis-service work require the system to be isolated and may be performed only by personnel authorised for the delivered integration.
81 +)))
82 +
83 +[[image:1788773598823-721.png]]
84 +
85 +
86 +|**Interface**|**Relevant signals**|**Diagnostic meaning**
87 +|X1 safety|Pins 1-4: dual emergency-stop circuits; 5-6: acknowledgement|Both channels and the approved acknowledgement must be valid before operation.
88 +|X1 shutter|Pins 7-10: dual shutter circuits; 11-12: acknowledgement|Opening the protective enclosure must interrupt the shutter circuit. Never bypass either channel.
89 +|X1 control|13: +24 V; 14: START; 15: STOP|Check the host command sequence only after the safety states are valid.
90 +|X1 status|16: E-stop; 17: SHUTTER; 18: READY; 19: BUSY; 20: END|Record which output is absent or changes first. Active outputs provide 24 V; maximum output current is 250 mA.
91 +|X2 axes|Direction/step for X, Y, Z, R; zero inputs|A motion or reference fault may belong to the host mechanics, axis wiring, limit/reference input, or configuration.
92 +
49 49  
1788773598823-721.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +146.5 KB
Inhalt