... ... @@ -27,4 +27,32 @@
27 27  |Signal state|(% style="width:764px" %)X1 emergency-stop, SHUTTER, LASER READY, LASER BUSY and LASER END; host guard and extraction states
28 28  |Timing and evidence|(% style="width:764px" %)Time, last successful cycle, recent change, error text, and safe photographs or screenshots
29 29  
30 -
30 +
31 +
32 += Safety, Readiness, and Unexpected Stops =
33 +
34 +(% class="box infomessage" %)
35 +(((
36 +Functions and movements are permitted only while no fault is present and all required devices are ready. If a start condition is lost during operation, the integrated laser cell must stop.
37 +)))
38 +
39 +|**Symptom**|**Likely cause**|**Safe check or action**
40 +|System will not power on|Mains supply absent; rear main switch off; damaged cable; host supply or protection device open|Keep the system off. Check the approved supply, plug and cable externally. Do not open the rack. Escalate damaged wiring or repeated tripping.
41 +|No LASER READY|Emergency-stop or shutter chain not acknowledged; guard/access condition open; controller or laser fault; integration sequence incomplete|Read the host and AnyMarker messages. Verify the guard, dual emergency-stop and dual shutter states, then perform only the approved acknowledgement/reset sequence.
42 +|SHUTTER status missing|Protective enclosure open; shutter circuit interrupted; acknowledgement missing; safety module fault|Close and secure the host enclosure. Confirm the host safety module reports both shutter channels healthy. Do not bridge the circuit.
43 +|Start command has no effect|LASER READY absent; external START not reaching X1.14; job not ready; another start condition missing|Confirm LASER READY first. Check the host command sequence and AnyMarker job state. Pin-level testing is for qualified integration personnel only.
44 +|Laser stops during a cycle|A start condition was lost; external STOP at X1.15; guard, emergency-stop, shutter, extraction or controller fault|Leave the system stopped. Record which status changed first. Correct the initiating condition; do not repeatedly reset a recurring fault.
45 +|BUSY or END sequence abnormal|Job/control communication issue; external control timing; controller fault|Record LASER READY/BUSY/END timing and the AnyMarker message. Check the approved host sequence; escalate if the sequence differs from the validated integration.
46 +
47 +
48 +
49 += No Mark, Weak Mark, or Long Cycle =
50 +
51 +|**Symptom**|**Possible cause**|**Safe check or action**
52 +|No visible mark|Safety permission absent; wrong job/device; unsuitable material; parameters produce no visible response|Confirm READY and SHUTTER status, the selected Auto-Light device and job, workpiece material, focus, and approved parameter assignment. Test only on an approved sample.
53 +|Mark is too weak|Incorrect Z value in the job or axis menu|Compare the commanded Z position with the validated setup. If an installed Z-axis has lost reference, stop and follow the approved axis-reference procedure before refocusing.
54 +|Mark is too weak|Focus is above or below the workpiece|Check the approved focal distance, fixture seating and workpiece height. Refocus before changing laser energy.
55 +|Mark is too weak|Objective contaminated or damaged|Stop and isolate the equipment. Inspect only as permitted by the maintenance procedure. Do not touch or clean optics unless trained and authorised.
56 +|Mark is too weak|Incorrect or unqualified parameters|Reload the validated recipe. If adjustment is authorised, change one controlled variable at a time and verify the result on an approved sample.
57 +|Marking takes too long|Low speed, insufficient effective energy, overly fine hatch spacing, too many passes, or unsuitable font|Compare the job with the released process. Use an approved plotter font where appropriate. Requalify any change that affects quality or cycle time.
58 +|Mark shifts or clips|Workpiece moved; fixture incorrect; pilot position, field, axis position or job origin changed|Stop emission. Secure the workpiece, verify the fixture and job origin with the pilot laser, and confirm axis position before another test.