System Overview and Safety Devices

Version 4.2 von jadomatis am 2026/09/08 09:42

Description: The Auto-Light combines a modular laser rack and marking head with interfaces for externally integrated safety, production control, and motion control. Learn about the system hardware,  the protective devices, and safeguards that must be completed by the host machine.

Safety basis - Class 4 integration laser: Auto-Light is not a self-contained Class 1 workstation. Do not release laser operation until the complete protective enclosure, access control, emergency-stop and shutter circuits, emission warning, extraction, and all configuration-specific protective measures have been installed, tested, validated, and documented.


Auto-Light System Overview

  • The laser rack contains the fibre-laser source and control hardware.
  • The marking head directs and scans the beam through the installed F-Theta lens.
  • The manual documents a 3 m fibre arrangement between the source and marking head.
  • A pilot laser supports workpiece positioning before production-laser emission.
  • An electrically controlled Z-axis establishes the required working distance in the documented configuration.
  • X1 connects external safety and production signals; X2 supports integrated X/Y/Z/R axis signals.
1788852299021-764.png

Auto-Light laser rack and marking head.

Operator and Connection Panels

1788852351064-324.png

Auto-Light front and rear panels. 

LocationDocumented items
Front panelShutter / laser key switch; status indicator; USB interface; cooling-air openings.
Rear panelHDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input.

 Ventilation clearance: Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage.

Protective Devices

Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it.

DeviceSafety function and limitationRequired condition
Main switchControls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure.
ShutterInterrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine.

Safety-Related Controls and Interfaces

Control / interfaceRole in the integrated system
Laser key switchHelps control authorized access to laser operation. Key control does not replace guarding or safety circuits.
Status indicatorSupports operating-state recognition. An indication alone is not proof that every safeguard is functional.
X1 emergency-stop circuitsProvides two external emergency-stop channels plus acknowledgement contacts for the host safety system.
X1 shutter circuitsProvides two external shutter channels plus acknowledgement contacts. Opening the protective enclosure must interrupt the shutter circuit.
X1 production/status I/OProvides external start/stop and emergency-stop, shutter, ready, busy, and end status signals. Production signals must never bypass safety permission.

Important Distinctions

  • The main switch is not an emergency-stop device and does not replace the required isolation procedure.
  • The shutter interrupts the beam, but it does not replace a complete laser-safe enclosure and access-control system.
  • The key switch helps prevent unauthorised operation, but it does not validate the safety chain.
  • Status outputs and indicators support control and diagnosis; they do not replace functional testing of safeguards.
1788852854245-428.png

Functional boundary between the host safety system and the Auto-Light.