Änderungen von Dokument System Overview and Safety Devices
Zuletzt geändert von jadomatis am 2026/09/08 10:37
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -11,7 +11,7 @@ 11 11 12 12 * The laser rack contains the fibre-laser source and control hardware. 13 13 * The marking head directs and scans the beam through the installed F-Theta lens. 14 -* A3 m fibre arrangement between the source and marking head.14 +* The manual documents a 3 m fibre arrangement between the source and marking head. 15 15 * A pilot laser supports workpiece positioning before production-laser emission. 16 16 * An electrically controlled Z-axis establishes the required working distance in the documented configuration. 17 17 * X1 connects external safety and production signals; X2 supports integrated X/Y/Z/R axis signals. ... ... @@ -63,7 +63,7 @@ 63 63 64 64 * The main switch is not an emergency-stop device and does not replace the required isolation procedure. 65 65 * The shutter interrupts the beam, but it does not replace a complete laser-safe enclosure and access-control system. 66 -* The key switch helps prevent unauthori zed operation, but it does not validate the safety chain.66 +* The key switch helps prevent unauthorised operation, but it does not validate the safety chain. 67 67 * Status outputs and indicators support control and diagnosis; they do not replace functional testing of safeguards. 68 68 69 69 ... ... @@ -75,7 +75,7 @@ 75 75 76 76 1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state. 77 77 1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking. 78 -1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, work holding, focus, and qualified job data - is satisfied.78 +1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied. 79 79 1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design. 80 80 81 81 (% class="box warningmessage" %) ... ... @@ -123,7 +123,7 @@ 123 123 * Test both emergency-stop channels, both shutter channels, acknowledgement functions, reset logic, and prevention of unexpected restart according to the approved validation procedure. 124 124 * Confirm that the main switch, laser key switch, and status indication are undamaged and behave as documented. 125 125 * Verify the external emission warning, hazard-area warning lights and signs, restricted access, and key-control procedure. 126 -* Inspect the rack, marking head, fib er, objective, cables, connectors, and required labels for visible damage or unauthorized modification.126 +* Inspect the rack, marking head, fibre, objective, cables, connectors, and required labels for visible damage or unauthorised modification. 127 127 * Keep the cooling openings clear and confirm that the environmental conditions are within the documented limits. 128 128 * Start and verify the approved extraction system before any marking test. 129 129 * Confirm secure work holding, correct focus, approved material and parameters, a clear hazard area, and qualified job data before enabling active mode. ... ... @@ -138,10 +138,10 @@ 138 138 = Response to a Safety-Device Fault = 139 139 140 140 1. Stop the current operation and use the emergency stop if an immediate hazard exists. 141 -1. Switch off the Auto-Light and prevent unauthori zed restart.141 +1. Switch off the Auto-Light and prevent unauthorised restart. 142 142 1. Record the indicator state, software or host-machine message, affected safeguard, system model, and serial number. 143 -1. Inspect only to the extent permitted for trained operating personnel. Do not open the laser source or energi zed electrical compartments.144 -1. Contact authori zed service or the responsible integrator when the cause is not an approved operator-level correction.143 +1. Inspect only to the extent permitted for trained operating personnel. Do not open the laser source or energised electrical compartments. 144 +1. Contact authorised service or the responsible integrator when the cause is not an approved operator-level correction. 145 145 1. After repair, repeat the documented functional and validation checks before releasing the integrated machine for production. 146 146 147 147