Änderungen von Dokument System Overview and Safety Devices

Zuletzt geändert von jadomatis am 2026/09/08 10:37

Von Version 4.7
bearbeitet von jadomatis
am 2026/09/08 10:37
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 4.6
bearbeitet von jadomatis
am 2026/09/08 10:35
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -11,7 +11,7 @@
11 11  
12 12  * The laser rack contains the fibre-laser source and control hardware.
13 13  * The marking head directs and scans the beam through the installed F-Theta lens.
14 -* A 3 m fibre arrangement between the source and marking head.
14 +* The manual documents a 3 m fibre arrangement between the source and marking head.
15 15  * A pilot laser supports workpiece positioning before production-laser emission.
16 16  * An electrically controlled Z-axis establishes the required working distance in the documented configuration.
17 17  * X1 connects external safety and production signals; X2 supports integrated X/Y/Z/R axis signals.
... ... @@ -63,7 +63,7 @@
63 63  
64 64  * The main switch is not an emergency-stop device and does not replace the required isolation procedure.
65 65  * The shutter interrupts the beam, but it does not replace a complete laser-safe enclosure and access-control system.
66 -* The key switch helps prevent unauthorized operation, but it does not validate the safety chain.
66 +* The key switch helps prevent unauthorised operation, but it does not validate the safety chain.
67 67  * Status outputs and indicators support control and diagnosis; they do not replace functional testing of safeguards.
68 68  
69 69  
... ... @@ -75,7 +75,7 @@
75 75  
76 76  1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state.
77 77  1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking.
78 -1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, work holding, focus, and qualified job data - is satisfied.
78 +1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied.
79 79  1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design.
80 80  
81 81  (% class="box warningmessage" %)
... ... @@ -123,7 +123,7 @@
123 123  * Test both emergency-stop channels, both shutter channels, acknowledgement functions, reset logic, and prevention of unexpected restart according to the approved validation procedure.
124 124  * Confirm that the main switch, laser key switch, and status indication are undamaged and behave as documented.
125 125  * Verify the external emission warning, hazard-area warning lights and signs, restricted access, and key-control procedure.
126 -* Inspect the rack, marking head, fiber, objective, cables, connectors, and required labels for visible damage or unauthorized modification.
126 +* Inspect the rack, marking head, fibre, objective, cables, connectors, and required labels for visible damage or unauthorised modification.
127 127  * Keep the cooling openings clear and confirm that the environmental conditions are within the documented limits.
128 128  * Start and verify the approved extraction system before any marking test.
129 129  * Confirm secure work holding, correct focus, approved material and parameters, a clear hazard area, and qualified job data before enabling active mode.
... ... @@ -138,10 +138,10 @@
138 138  = Response to a Safety-Device Fault =
139 139  
140 140  1. Stop the current operation and use the emergency stop if an immediate hazard exists.
141 -1. Switch off the Auto-Light and prevent unauthorized restart.
141 +1. Switch off the Auto-Light and prevent unauthorised restart.
142 142  1. Record the indicator state, software or host-machine message, affected safeguard, system model, and serial number.
143 -1. Inspect only to the extent permitted for trained operating personnel. Do not open the laser source or energized electrical compartments.
144 -1. Contact authorized service or the responsible integrator when the cause is not an approved operator-level correction.
143 +1. Inspect only to the extent permitted for trained operating personnel. Do not open the laser source or energised electrical compartments.
144 +1. Contact authorised service or the responsible integrator when the cause is not an approved operator-level correction.
145 145  1. After repair, repeat the documented functional and validation checks before releasing the integrated machine for production.
146 146  
147 147