Last modified by jadomatis on 2026/09/08 10:37

From version 4.4
edited by jadomatis
on 2026/09/08 09:51
Change comment: There is no comment for this version
To version 4.5
edited by jadomatis
on 2026/09/08 10:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -102,7 +102,7 @@
102 102  
103 103  (% class="box errormessage" %)
104 104  (((
105 - **Class 4 open operation: **If the laser is operated without an effective protective enclosure, the entire controlled hazard area must be managed for Class 4 radiation. The manual requires restricted access, warning lights and signs, a visible emission warning, and laser safety glasses matched to the installed wavelength and power. These measures do not replace any additional legal or site-specific requirement.
105 + **Class 4 open operation: **If the laser is operated without an effective protective enclosure, the entire controlled hazard area must be managed for Class 4 radiation. The work requires restricted access, warning lights and signs, a visible emission warning, and laser safety glasses matched to the installed wavelength and power. These measures do not replace any additional legal or site-specific requirement.
106 106  )))
107 107  
108 108  
... ... @@ -114,4 +114,34 @@
114 114  * Emergency-stop acknowledgement through X1 is required at every system restart and after every emergency-stop actuation.
115 115  * Acknowledgement may be accepted only after the cause has been removed and the hazard area is clear. It must not initiate laser emission or hazardous motion by itself.
116 116  
117 +
118 +
119 += Pre-Operation Safety-Device Check =
120 +
121 +* Confirm that the protective enclosure, guards, service covers, and laser-protection components are installed, intact, secured, and suitable for the delivered laser source.
122 +* Confirm that opening every guarded access point interrupts shutter permission and prevents laser marking.
123 +* Test both emergency-stop channels, both shutter channels, acknowledgement functions, reset logic, and prevention of unexpected restart according to the approved validation procedure.
124 +* Confirm that the main switch, laser key switch, and status indication are undamaged and behave as documented.
125 +* Verify the external emission warning, hazard-area warning lights and signs, restricted access, and key-control procedure.
126 +* Inspect the rack, marking head, fibre, objective, cables, connectors, and required labels for visible damage or unauthorised modification.
127 +* Keep the cooling openings clear and confirm that the environmental conditions are within the documented limits.
128 +* Start and verify the approved extraction system before any marking test.
129 +* Confirm secure workholding, correct focus, approved material and parameters, a clear hazard area, and qualified job data before enabling active mode.
130 +
131 +(% class="box errormessage" %)
132 +(((
133 +**Stop operation: **Do not use the Auto-Light if a safeguard, warning, enclosure component, circuit, acknowledgement, status signal, extraction system, label, or machine component is missing, damaged, bypassed, incorrectly adjusted, or behaving unexpectedly
134 +)))
135 +
136 +
137 +
138 += Response to a Safety-Device Fault =
139 +
140 +1. Stop the current operation and use the emergency stop if an immediate hazard exists.
141 +1. Switch off the Auto-Light and prevent unauthorised restart.
142 +1. Record the indicator state, software or host-machine message, affected safeguard, system model, and serial number.
143 +1. Inspect only to the extent permitted for trained operating personnel. Do not open the laser source or energised electrical compartments.
144 +1. Contact authorised service or the responsible integrator when the cause is not an approved operator-level correction.
145 +1. After repair, repeat the documented functional and validation checks before releasing the integrated machine for production.
146 +
117 117