88 += Safeguards Completed by the Host Machine =
88 88  
90 +The system integrator and user company must establish the complete safety concept for the installed machine. At minimum, assess and implement the following requirements for the delivered configuration and installation site:
91 +
92 +* A laser-safe protective enclosure suitable for the installed wavelength, output, beam path, and foreseeable reflections.
93 +* Controlled access and guard monitoring that prevent exposure and interrupt the shutter circuit whenever the enclosure is opened.
94 +* An approved external safety module connected to both emergency-stop channels and both shutter channels through X1.
95 +* Emergency-stop devices, safe reset logic, acknowledgement behaviour, prevention of unexpected restart, and documented validation of the complete safety function.
96 +* External warning signs and warning lights identifying the Class 4 hazard area, plus an emission warning visible to the operator.
97 +* Restricted access and key control that prevent unauthorised operation.
98 +* Suitable extraction for gases, vapours, aerosols, and dust generated by the approved marking process.
99 +* Fire and explosion precautions appropriate to the workpiece, coating, residues, extraction system, and selected parameters.
100 +* Safe workholding, guarded axis motion, travel limits, homing behaviour, and production-control logic.
101 +* Training, written responsibilities, applicable personal protective equipment, and appointment of a laser safety officer where required by local regulations.
102 +
103 +(% class="box errormessage" %)
104 +(((
105 + **Class 4 open operation: **If the laser is operated without an effective protective enclosure, the entire controlled hazard area must be managed for Class 4 radiation. The work requires restricted access, warning lights and signs, a visible emission warning, and laser safety glasses matched to the installed wavelength and power. These measures do not replace any additional legal or site-specific requirement.
106 +)))
107 +
108 +
109 +
110 += Shutter and Emergency-Stop Behaviour =
111 +
112 +* Opening the protective enclosure must interrupt the external shutter circuit.
113 +* Closing and validating the shutter circuit permits active mode; laser energy can be emitted only in active mode.
114 +* Emergency-stop acknowledgement through X1 is required at every system restart and after every emergency-stop actuation.
115 +* Acknowledgement may be accepted only after the cause has been removed and the hazard area is clear. It must not initiate laser emission or hazardous motion by itself.
116 +
117 +
118 +
119 += Pre-Operation Safety-Device Check =
120 +
121 +* Confirm that the protective enclosure, guards, service covers, and laser-protection components are installed, intact, secured, and suitable for the delivered laser source.
122 +* Confirm that opening every guarded access point interrupts shutter permission and prevents laser marking.
123 +* Test both emergency-stop channels, both shutter channels, acknowledgement functions, reset logic, and prevention of unexpected restart according to the approved validation procedure.
124 +* Confirm that the main switch, laser key switch, and status indication are undamaged and behave as documented.
125 +* Verify the external emission warning, hazard-area warning lights and signs, restricted access, and key-control procedure.
126 +* Inspect the rack, marking head, fibre, objective, cables, connectors, and required labels for visible damage or unauthorised modification.
127 +* Keep the cooling openings clear and confirm that the environmental conditions are within the documented limits.
128 +* Start and verify the approved extraction system before any marking test.
129 +* Confirm secure workholding, correct focus, approved material and parameters, a clear hazard area, and qualified job data before enabling active mode.
130 +
131 +(% class="box errormessage" %)
132 +(((
133 +**Stop operation: **Do not use the Auto-Light if a safeguard, warning, enclosure component, circuit, acknowledgement, status signal, extraction system, label, or machine component is missing, damaged, bypassed, incorrectly adjusted, or behaving unexpectedly
134 +)))
135 +
136 +
137 +
138 += Response to a Safety-Device Fault =
139 +
140 +1. Stop the current operation and use the emergency stop if an immediate hazard exists.
141 +1. Switch off the Auto-Light and prevent unauthorised restart.
142 +1. Record the indicator state, software or host-machine message, affected safeguard, system model, and serial number.
143 +1. Inspect only to the extent permitted for trained operating personnel. Do not open the laser source or energised electrical compartments.
144 +1. Contact authorised service or the responsible integrator when the cause is not an approved operator-level correction.
145 +1. After repair, repeat the documented functional and validation checks before releasing the integrated machine for production.
146 +
89 89