Last modified by jadomatis on 2026/09/08 10:37

From version 4.3
edited by jadomatis
on 2026/09/08 09:44
Change comment: There is no comment for this version
To version 4.2
edited by jadomatis
on 2026/09/08 09:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -68,22 +68,10 @@
68 68  
69 69  
70 70  
71 -[[**Functional boundary between the host safety system and the Auto-Light.**>>image:1788852854245-428.png]]
71 +[[Functional boundary between the host safety system and the Auto-Light.>>image:1788852854245-428.png]]
72 72  
73 73  
74 -= How the Safety Chain Works =
74 +\\
75 75  
76 -1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state.
77 -1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking.
78 -1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied.
79 -1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design.
80 80  
81 -(% class="box warningmessage" %)
82 -(((
83 -**Permission is not a command: **A closed shutter circuit permits active mode. It must never initiate marking by itself, and it is not proof that the complete host safety system has been validated.
84 -)))
85 -
86 -
87 -
88 -
89 89