Änderungen von Dokument System Overview and Safety Devices
Zuletzt geändert von jadomatis am 2026/09/08 10:37
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -68,22 +68,4 @@ 68 68 69 69 70 70 71 -[[**Functional boundary between the host safety system and the Auto-Light.**>>image:1788852854245-428.png]] 72 - 73 - 74 -= How the Safety Chain Works = 75 - 76 -1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state. 77 -1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking. 78 -1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied. 79 -1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design. 80 - 81 -(% class="box warningmessage" %) 82 -((( 83 -**Permission is not a command: **A closed shutter circuit permits active mode. It must never initiate marking by itself, and it is not proof that the complete host safety system has been validated. 84 -))) 85 - 86 - 87 - 88 - 89 89