Änderungen von Dokument System Overview and Safety Devices
Zuletzt geändert von jadomatis am 2026/09/08 10:37
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
-
Anhänge (0 geändert, 0 hinzugefügt, 1 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -33,57 +33,3 @@ 33 33 ((( 34 34 **Ventilation clearance: **Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage. 35 35 ))) 36 - 37 - 38 - 39 -= Protective Devices = 40 - 41 -Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it. 42 - 43 -(% class="table-condensed table-striped" style="width:1428px" %) 44 -|**Device**|(% style="width:727px" %)**Safety function and limitation**|(% style="width:624px" %)**Required condition** 45 -|Main switch|(% style="width:727px" %)Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|(% style="width:624px" %)Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure. 46 -|Shutter|(% style="width:727px" %)Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|(% style="width:624px" %)Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine. 47 - 48 - 49 - 50 -= Safety-Related Controls and Interfaces = 51 - 52 -(% class="table-condensed table-striped" style="width:1250px" %) 53 -|**Control / interface**|(% style="width:1006px" %)**Role in the integrated system** 54 -|Laser key switch|(% style="width:1006px" %)Helps control authorized access to laser operation. Key control does not replace guarding or safety circuits. 55 -|Status indicator|(% style="width:1006px" %)Supports operating-state recognition. An indication alone is not proof that every safeguard is functional. 56 -|X1 emergency-stop circuits|(% style="width:1006px" %)Provides two external emergency-stop channels plus acknowledgement contacts for the host safety system. 57 -|X1 shutter circuits|(% style="width:1006px" %)Provides two external shutter channels plus acknowledgement contacts. Opening the protective enclosure must interrupt the shutter circuit. 58 -|X1 production/status I/O|(% style="width:1006px" %)Provides external start/stop and emergency-stop, shutter, ready, busy, and end status signals. Production signals must never bypass safety permission. 59 - 60 - 61 - 62 -= Important Distinctions = 63 - 64 -* The main switch is not an emergency-stop device and does not replace the required isolation procedure. 65 -* The shutter interrupts the beam, but it does not replace a complete laser-safe enclosure and access-control system. 66 -* The key switch helps prevent unauthorised operation, but it does not validate the safety chain. 67 -* Status outputs and indicators support control and diagnosis; they do not replace functional testing of safeguards. 68 - 69 - 70 - 71 -[[**Functional boundary between the host safety system and the Auto-Light.**>>image:1788852854245-428.png]] 72 - 73 - 74 -= How the Safety Chain Works = 75 - 76 -1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state. 77 -1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking. 78 -1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied. 79 -1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design. 80 - 81 -(% class="box warningmessage" %) 82 -((( 83 -**Permission is not a command: **A closed shutter circuit permits active mode. It must never initiate marking by itself, and it is not proof that the complete host safety system has been validated. 84 -))) 85 - 86 - 87 - 88 - 89 -
- 1788852854245-428.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Größe
-
... ... @@ -1,1 +1,0 @@ 1 -86.4 KB - Inhalt