71 +[[**Functional boundary between the host safety system and the Auto-Light.**>>image:1788852854245-428.png]]
72 +
73 +
74 += How the Safety Chain Works =
75 +
76 +1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state.
77 +1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking.
78 +1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied.
79 +1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design.
80 +
81 +(% class="box warningmessage" %)
82 +(((
83 +**Permission is not a command: **A closed shutter circuit permits active mode. It must never initiate marking by itself, and it is not proof that the complete host safety system has been validated.
84 +)))