Änderungen von Dokument System Overview and Safety Devices
Zuletzt geändert von jadomatis am 2026/09/08 10:37
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
-
Anhänge (0 geändert, 0 hinzugefügt, 1 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -40,32 +40,8 @@ 40 40 41 41 Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it. 42 42 43 -(% class="table-condensed table-striped" style="width:1428px" %) 44 -|**Device**|(% style="width:727px" %)**Safety function and limitation**|(% style="width:624px" %)**Required condition** 45 -|Main switch|(% style="width:727px" %)Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|(% style="width:624px" %)Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure. 46 -|Shutter|(% style="width:727px" %)Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|(% style="width:624px" %)Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine. 43 +|**Device**|**Safety function and limitation**|**Required condition** 44 +|Main switch|Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure. 45 +|Shutter|Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine. 47 47 48 - 49 - 50 -= Safety-Related Controls and Interfaces = 51 - 52 -(% class="table-condensed table-striped" style="width:1250px" %) 53 -|**Control / interface**|(% style="width:1006px" %)**Role in the integrated system** 54 -|Laser key switch|(% style="width:1006px" %)Helps control authorized access to laser operation. Key control does not replace guarding or safety circuits. 55 -|Status indicator|(% style="width:1006px" %)Supports operating-state recognition. An indication alone is not proof that every safeguard is functional. 56 -|X1 emergency-stop circuits|(% style="width:1006px" %)Provides two external emergency-stop channels plus acknowledgement contacts for the host safety system. 57 -|X1 shutter circuits|(% style="width:1006px" %)Provides two external shutter channels plus acknowledgement contacts. Opening the protective enclosure must interrupt the shutter circuit. 58 -|X1 production/status I/O|(% style="width:1006px" %)Provides external start/stop and emergency-stop, shutter, ready, busy, and end status signals. Production signals must never bypass safety permission. 59 - 60 - 61 - 62 -= Important Distinctions = 63 - 64 -* The main switch is not an emergency-stop device and does not replace the required isolation procedure. 65 -* The shutter interrupts the beam, but it does not replace a complete laser-safe enclosure and access-control system. 66 -* The key switch helps prevent unauthorised operation, but it does not validate the safety chain. 67 -* Status outputs and indicators support control and diagnosis; they do not replace functional testing of safeguards. 68 - 69 - 70 - 71 71
- 1788852854245-428.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Größe
-
... ... @@ -1,1 +1,0 @@ 1 -86.4 KB - Inhalt