Last modified by jadomatis on 2026/09/08 10:37

From version 3.5
edited by jadomatis
on 2026/09/08 09:41
Change comment: There is no comment for this version
To version 4.3
edited by jadomatis
on 2026/09/08 09:44
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -68,4 +68,22 @@
68 68  
69 69  
70 70  
71 +[[**Functional boundary between the host safety system and the Auto-Light.**>>image:1788852854245-428.png]]
72 +
73 +
74 += How the Safety Chain Works =
75 +
76 +1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state.
77 +1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking.
78 +1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied.
79 +1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design.
80 +
81 +(% class="box warningmessage" %)
82 +(((
83 +**Permission is not a command: **A closed shutter circuit permits active mode. It must never initiate marking by itself, and it is not proof that the complete host safety system has been validated.
84 +)))
85 +
86 +
87 +
88 +
71 71  
1788852854245-428.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +86.4 KB
Content