Changes for page System Overview and Safety Devices
Last modified by jadomatis on 2026/09/08 10:37
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -68,4 +68,22 @@ 68 68 69 69 70 70 71 +[[**Functional boundary between the host safety system and the Auto-Light.**>>image:1788852854245-428.png]] 72 + 73 + 74 += How the Safety Chain Works = 75 + 76 +1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state. 77 +1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking. 78 +1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied. 79 +1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design. 80 + 81 +(% class="box warningmessage" %) 82 +((( 83 +**Permission is not a command: **A closed shutter circuit permits active mode. It must never initiate marking by itself, and it is not proof that the complete host safety system has been validated. 84 +))) 85 + 86 + 87 + 88 + 71 71
- 1788852854245-428.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.4 KB - Content