Changes for page System Overview and Safety Devices
Last modified by jadomatis on 2026/09/08 10:37
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,65 +7,4 @@ 7 7 8 8 ---- 9 9 10 -= Auto-Light System Overview = 11 - 12 -* The laser rack contains the fibre-laser source and control hardware. 13 -* The marking head directs and scans the beam through the installed F-Theta lens. 14 -* The manual documents a 3 m fibre arrangement between the source and marking head. 15 -* A pilot laser supports workpiece positioning before production-laser emission. 16 -* An electrically controlled Z-axis establishes the required working distance in the documented configuration. 17 -* X1 connects external safety and production signals; X2 supports integrated X/Y/Z/R axis signals. 18 - 19 -[[**Auto-Light laser rack and marking head.**>>image:1788852299021-764.png]] 20 - 21 - 22 -= Operator and Connection Panels = 23 - 24 -[[**Auto-Light front and rear panels. **>>image:1788852351064-324.png]] 25 - 26 - 27 -(% class="table-condensed table-striped" style="width:840px" %) 28 -|**Location**|(% style="width:628px" %)**Documented items** 29 -|Front panel|(% style="width:628px" %)Shutter / laser key switch; status indicator; USB interface; cooling-air openings. 30 -|Rear panel|(% style="width:628px" %)HDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input. 31 - 32 -(% class="box warningmessage" %) 33 -((( 34 - **Ventilation clearance: **Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage. 35 -))) 36 - 37 - 38 - 39 -= Protective Devices = 40 - 41 -Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it. 42 - 43 -(% class="table-condensed table-striped" style="width:1428px" %) 44 -|**Device**|(% style="width:727px" %)**Safety function and limitation**|(% style="width:624px" %)**Required condition** 45 -|Main switch|(% style="width:727px" %)Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|(% style="width:624px" %)Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure. 46 -|Shutter|(% style="width:727px" %)Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|(% style="width:624px" %)Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine. 47 - 48 - 49 - 50 -= Safety-Related Controls and Interfaces = 51 - 52 -(% class="table-condensed table-striped" style="width:1250px" %) 53 -|**Control / interface**|(% style="width:1006px" %)**Role in the integrated system** 54 -|Laser key switch|(% style="width:1006px" %)Helps control authorized access to laser operation. Key control does not replace guarding or safety circuits. 55 -|Status indicator|(% style="width:1006px" %)Supports operating-state recognition. An indication alone is not proof that every safeguard is functional. 56 -|X1 emergency-stop circuits|(% style="width:1006px" %)Provides two external emergency-stop channels plus acknowledgement contacts for the host safety system. 57 -|X1 shutter circuits|(% style="width:1006px" %)Provides two external shutter channels plus acknowledgement contacts. Opening the protective enclosure must interrupt the shutter circuit. 58 -|X1 production/status I/O|(% style="width:1006px" %)Provides external start/stop and emergency-stop, shutter, ready, busy, and end status signals. Production signals must never bypass safety permission. 59 - 60 - 61 - 62 -= Important Distinctions = 63 - 64 -* The main switch is not an emergency-stop device and does not replace the required isolation procedure. 65 -* The shutter interrupts the beam, but it does not replace a complete laser-safe enclosure and access-control system. 66 -* The key switch helps prevent unauthorised operation, but it does not validate the safety chain. 67 -* Status outputs and indicators support control and diagnosis; they do not replace functional testing of safeguards. 68 - 69 - 70 - 71 71
- 1788852299021-764.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -455.0 KB - Content
- 1788852351064-324.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.jadomatis - Size
-
... ... @@ -1,1 +1,0 @@ 1 -412.1 KB - Content