41 41  Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it.
42 42  
43 -|**Device**|**Safety function and limitation**|**Required condition**
44 -|Main switch|Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure.
45 -|Shutter|Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine.
43 +(% class="table-condensed table-striped" style="width:1428px" %)
44 +|**Device**|(% style="width:727px" %)**Safety function and limitation**|(% style="width:624px" %)**Required condition**
45 +|Main switch|(% style="width:727px" %)Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|(% style="width:624px" %)Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure.
46 +|Shutter|(% style="width:727px" %)Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|(% style="width:624px" %)Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine.
46 46  
48 +
49 +
50 += Safety-Related Controls and Interfaces =
51 +
52 +(% class="table-condensed table-striped" style="width:1250px" %)
53 +|**Control / interface**|(% style="width:1006px" %)**Role in the integrated system**
54 +|Laser key switch|(% style="width:1006px" %)Helps control authorized access to laser operation. Key control does not replace guarding or safety circuits.
55 +|Status indicator|(% style="width:1006px" %)Supports operating-state recognition. An indication alone is not proof that every safeguard is functional.
56 +|X1 emergency-stop circuits|(% style="width:1006px" %)Provides two external emergency-stop channels plus acknowledgement contacts for the host safety system.
57 +|X1 shutter circuits|(% style="width:1006px" %)Provides two external shutter channels plus acknowledgement contacts. Opening the protective enclosure must interrupt the shutter circuit.
58 +|X1 production/status I/O|(% style="width:1006px" %)Provides external start/stop and emergency-stop, shutter, ready, busy, and end status signals. Production signals must never bypass safety permission.
59 +
60 +
61 +
62 += Important Distinctions =
63 +
64 +* The main switch is not an emergency-stop device and does not replace the required isolation procedure.
65 +* The shutter interrupts the beam, but it does not replace a complete laser-safe enclosure and access-control system.
66 +* The key switch helps prevent unauthorised operation, but it does not validate the safety chain.
67 +* Status outputs and indicators support control and diagnosis; they do not replace functional testing of safeguards.
68 +
69 +
70 +
71 +[[**Functional boundary between the host safety system and the Auto-Light.**>>image:1788852854245-428.png]]
72 +
73 +
74 += How the Safety Chain Works =
75 +
76 +1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state.
77 +1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking.
78 +1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied.
79 +1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design.
80 +
81 +(% class="box warningmessage" %)
82 +(((
83 +**Permission is not a command: **A closed shutter circuit permits active mode. It must never initiate marking by itself, and it is not proof that the complete host safety system has been validated.
84 +)))
85 +
86 +
87 +
88 +