Changes for page System Overview and Safety Devices
Last modified by jadomatis on 2026/09/08 10:37
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,41 +7,4 @@ 7 7 8 8 ---- 9 9 10 -= Auto-Light System Overview = 11 - 12 -* The laser rack contains the fibre-laser source and control hardware. 13 -* The marking head directs and scans the beam through the installed F-Theta lens. 14 -* The manual documents a 3 m fibre arrangement between the source and marking head. 15 -* A pilot laser supports workpiece positioning before production-laser emission. 16 -* An electrically controlled Z-axis establishes the required working distance in the documented configuration. 17 -* X1 connects external safety and production signals; X2 supports integrated X/Y/Z/R axis signals. 18 - 19 -[[**Auto-Light laser rack and marking head.**>>image:1788852299021-764.png]] 20 - 21 - 22 -= Operator and Connection Panels = 23 - 24 -[[**Auto-Light front and rear panels. **>>image:1788852351064-324.png]] 25 - 26 - 27 -(% class="table-condensed table-striped" style="width:840px" %) 28 -|**Location**|(% style="width:628px" %)**Documented items** 29 -|Front panel|(% style="width:628px" %)Shutter / laser key switch; status indicator; USB interface; cooling-air openings. 30 -|Rear panel|(% style="width:628px" %)HDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input. 31 - 32 -(% class="box warningmessage" %) 33 -((( 34 - **Ventilation clearance: **Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage. 35 -))) 36 - 37 - 38 - 39 -= Protective Devices = 40 - 41 -Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it. 42 - 43 -|**Device**|**Safety function and limitation**|**Required condition** 44 -|Main switch|Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure. 45 -|Shutter|Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine. 46 - 47 47