... ... @@ -33,3 +33,15 @@
33 33  (((
34 34   **Ventilation clearance: **Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage.
35 35  )))
36 +
37 +
38 +
39 += Protective Devices =
40 +
41 +Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it.
42 +
43 +|**Device**|**Safety function and limitation**|**Required condition**
44 +|Main switch|Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure.
45 +|Shutter|Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine.
46 +