Changes for page System Overview and Safety Devices
Last modified by jadomatis on 2026/09/08 10:37
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,12 +21,69 @@ 21 21 22 22 = Operator and Connection Panels = 23 23 24 -[[image:1788852351064-324.png]] 24 +[[**Auto-Light front and rear panels. **>>image:1788852351064-324.png]] 25 25 26 -//Figure 2 - Auto-Light front and rear panels. English callouts are based on manual Section 7.// 27 27 28 -|**Location**|**Documented items** 29 -|Front panel|Shutter / laser key switch; status indicator; USB interface; cooling-air openings. 30 -|Rear panel|HDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input. 27 +(% class="table-condensed table-striped" style="width:840px" %) 28 +|**Location**|(% style="width:628px" %)**Documented items** 29 +|Front panel|(% style="width:628px" %)Shutter / laser key switch; status indicator; USB interface; cooling-air openings. 30 +|Rear panel|(% style="width:628px" %)HDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input. 31 31 32 +(% class="box warningmessage" %) 33 +((( 34 + **Ventilation clearance: **Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage. 35 +))) 36 + 37 + 38 + 39 += Protective Devices = 40 + 41 +Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it. 42 + 43 +(% class="table-condensed table-striped" style="width:1428px" %) 44 +|**Device**|(% style="width:727px" %)**Safety function and limitation**|(% style="width:624px" %)**Required condition** 45 +|Main switch|(% style="width:727px" %)Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|(% style="width:624px" %)Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure. 46 +|Shutter|(% style="width:727px" %)Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|(% style="width:624px" %)Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine. 47 + 48 + 49 + 50 += Safety-Related Controls and Interfaces = 51 + 52 +(% class="table-condensed table-striped" style="width:1250px" %) 53 +|**Control / interface**|(% style="width:1006px" %)**Role in the integrated system** 54 +|Laser key switch|(% style="width:1006px" %)Helps control authorized access to laser operation. Key control does not replace guarding or safety circuits. 55 +|Status indicator|(% style="width:1006px" %)Supports operating-state recognition. An indication alone is not proof that every safeguard is functional. 56 +|X1 emergency-stop circuits|(% style="width:1006px" %)Provides two external emergency-stop channels plus acknowledgement contacts for the host safety system. 57 +|X1 shutter circuits|(% style="width:1006px" %)Provides two external shutter channels plus acknowledgement contacts. Opening the protective enclosure must interrupt the shutter circuit. 58 +|X1 production/status I/O|(% style="width:1006px" %)Provides external start/stop and emergency-stop, shutter, ready, busy, and end status signals. Production signals must never bypass safety permission. 59 + 60 + 61 + 62 += Important Distinctions = 63 + 64 +* The main switch is not an emergency-stop device and does not replace the required isolation procedure. 65 +* The shutter interrupts the beam, but it does not replace a complete laser-safe enclosure and access-control system. 66 +* The key switch helps prevent unauthorised operation, but it does not validate the safety chain. 67 +* Status outputs and indicators support control and diagnosis; they do not replace functional testing of safeguards. 68 + 69 + 70 + 71 +[[**Functional boundary between the host safety system and the Auto-Light.**>>image:1788852854245-428.png]] 72 + 73 + 74 += How the Safety Chain Works = 75 + 76 +1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state. 77 +1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking. 78 +1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied. 79 +1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design. 80 + 81 +(% class="box warningmessage" %) 82 +((( 83 +**Permission is not a command: **A closed shutter circuit permits active mode. It must never initiate marking by itself, and it is not proof that the complete host safety system has been validated. 84 +))) 85 + 86 + 87 + 88 + 32 32
- 1788852854245-428.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.4 KB - Content