22 22  = Operator and Connection Panels =
23 23  
24 -[[image:1788852351064-324.png]]
24 +[[**Auto-Light front and rear panels. **>>image:1788852351064-324.png]]
25 25  
26 -//Figure 2 - Auto-Light front and rear panels. English callouts are based on manual Section 7.//
27 27  
28 -|**Location**|**Documented items**
29 -|Front panel|Shutter / laser key switch; status indicator; USB interface; cooling-air openings.
30 -|Rear panel|HDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input.
27 +(% class="table-condensed table-striped" style="width:840px" %)
28 +|**Location**|(% style="width:628px" %)**Documented items**
29 +|Front panel|(% style="width:628px" %)Shutter / laser key switch; status indicator; USB interface; cooling-air openings.
30 +|Rear panel|(% style="width:628px" %)HDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input.
31 31  
32 +(% class="box warningmessage" %)
33 +(((
34 + **Ventilation clearance: **Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage.
35 +)))
36 +
37 +
38 +
39 += Protective Devices =
40 +
41 +Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it.
42 +
43 +|**Device**|**Safety function and limitation**|**Required condition**
44 +|Main switch|Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure.
45 +|Shutter|Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine.
46 +