Summary

Details

Page properties
Content
... ... @@ -7,4 +7,141 @@
7 7  
8 8  ----
9 9  
10 += Auto-Light System Overview =
11 +
12 +* The laser rack contains the fiber-laser source and control hardware.
13 +* The marking head directs and scans the beam through the installed F-Theta lens.
14 +* A 3 m fiber arrangement between the source and marking head.
15 +* A pilot laser supports workpiece positioning before production-laser emission.
16 +* An electrically controlled Z-axis establishes the required working distance in the documented configuration.
17 +* X1 connects external safety and production signals; X2 supports integrated X/Y/Z/R axis signals.
18 +
19 +[[**Auto-Light laser rack and marking head.**>>image:1788852299021-764.png]]
20 +
21 +
22 += Operator and Connection Panels =
23 +
24 +[[**Auto-Light front and rear panels. **>>image:1788852351064-324.png]]
25 +
26 +
27 +(% class="table-condensed table-striped" style="width:840px" %)
28 +|**Location**|(% style="width:628px" %)**Documented items**
29 +|Front panel|(% style="width:628px" %)Shutter / laser key switch; status indicator; USB interface; cooling-air openings.
30 +|Rear panel|(% style="width:628px" %)HDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input.
31 +
32 +(% class="box warningmessage" %)
33 +(((
34 + **Ventilation clearance: **Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage.
35 +)))
36 +
37 +
38 +
39 += Protective Devices =
40 +
41 +Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it.
42 +
43 +(% class="table-condensed table-striped" style="width:1428px" %)
44 +|**Device**|(% style="width:727px" %)**Safety function and limitation**|(% style="width:624px" %)**Required condition**
45 +|Main switch|(% style="width:727px" %)Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|(% style="width:624px" %)Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure.
46 +|Shutter|(% style="width:727px" %)Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|(% style="width:624px" %)Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine.
47 +
48 +
49 +
50 += Safety-Related Controls and Interfaces =
51 +
52 +(% class="table-condensed table-striped" style="width:1250px" %)
53 +|**Control / interface**|(% style="width:1006px" %)**Role in the integrated system**
54 +|Laser key switch|(% style="width:1006px" %)Helps control authorized access to laser operation. Key control does not replace guarding or safety circuits.
55 +|Status indicator|(% style="width:1006px" %)Supports operating-state recognition. An indication alone is not proof that every safeguard is functional.
56 +|X1 emergency-stop circuits|(% style="width:1006px" %)Provides two external emergency-stop channels plus acknowledgement contacts for the host safety system.
57 +|X1 shutter circuits|(% style="width:1006px" %)Provides two external shutter channels plus acknowledgement contacts. Opening the protective enclosure must interrupt the shutter circuit.
58 +|X1 production/status I/O|(% style="width:1006px" %)Provides external start/stop and emergency-stop, shutter, ready, busy, and end status signals. Production signals must never bypass safety permission.
59 +
60 +
61 +
62 += Important Distinctions =
63 +
64 +* The main switch is not an emergency-stop device and does not replace the required isolation procedure.
65 +* The shutter interrupts the beam, but it does not replace a complete laser-safe enclosure and access-control system.
66 +* The key switch helps prevent unauthorized operation, but it does not validate the safety chain.
67 +* Status outputs and indicators support control and diagnosis; they do not replace functional testing of safeguards.
68 +
69 +
70 +
71 +[[**Functional boundary between the host safety system and the Auto-Light.**>>image:1788852854245-428.png]]
72 +
73 +
74 += How the Safety Chain Works =
75 +
76 +1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state.
77 +1. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking.
78 +1. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, work holding, focus, and qualified job data - is satisfied.
79 +1. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design.
80 +
81 +(% class="box warningmessage" %)
82 +(((
83 +**Permission is not a command: **A closed shutter circuit permits active mode. It must never initiate marking by itself, and it is not proof that the complete host safety system has been validated.
84 +)))
85 +
86 +
87 +
88 += Safeguards Completed by the Host Machine =
89 +
90 +The system integrator and user company must establish the complete safety concept for the installed machine. At minimum, assess and implement the following requirements for the delivered configuration and installation site:
91 +
92 +* A laser-safe protective enclosure suitable for the installed wavelength, output, beam path, and foreseeable reflections.
93 +* Controlled access and guard monitoring that prevent exposure and interrupt the shutter circuit whenever the enclosure is opened.
94 +* An approved external safety module connected to both emergency-stop channels and both shutter channels through X1.
95 +* Emergency-stop devices, safe reset logic, acknowledgement behavior, prevention of unexpected restart, and documented validation of the complete safety function.
96 +* External warning signs and warning lights identifying the Class 4 hazard area, plus an emission warning visible to the operator.
97 +* Restricted access and key control that prevent unauthorized operation.
98 +* Suitable extraction for gases, vapors, aerosols, and dust generated by the approved marking process.
99 +* Fire and explosion precautions appropriate to the workpiece, coating, residues, extraction system, and selected parameters.
100 +* Safe work holding, guarded axis motion, travel limits, homing behavior, and production-control logic.
101 +* Training, written responsibilities, applicable personal protective equipment, and appointment of a laser safety officer where required by local regulations.
102 +
103 +(% class="box errormessage" %)
104 +(((
105 + **Class 4 open operation: **If the laser is operated without an effective protective enclosure, the entire controlled hazard area must be managed for Class 4 radiation. The workspace requires restricted access, warning lights and signs, a visible emission warning, and laser safety glasses matched to the installed wavelength and power. These measures do not replace any additional legal or site-specific requirement.
106 +)))
107 +
108 +
109 +
110 += Shutter and Emergency-Stop Behavior =
111 +
112 +* Opening the protective enclosure must interrupt the external shutter circuit.
113 +* Closing and validating the shutter circuit permits active mode; laser energy can be emitted only in active mode.
114 +* Emergency-stop acknowledgement through X1 is required at every system restart and after every emergency-stop actuation.
115 +* Acknowledgement may be accepted only after the cause has been removed and the hazard area is clear. It must not initiate laser emission or hazardous motion by itself.
116 +
117 +
118 +
119 += Pre-Operation Safety-Device Check =
120 +
121 +* Confirm that the protective enclosure, guards, service covers, and laser-protection components are installed, intact, secured, and suitable for the delivered laser source.
122 +* Confirm that opening every guarded access point interrupts shutter permission and prevents laser marking.
123 +* Test both emergency-stop channels, both shutter channels, acknowledgement functions, reset logic, and prevention of unexpected restart according to the approved validation procedure.
124 +* Confirm that the main switch, laser key switch, and status indication are undamaged and behave as documented.
125 +* Verify the external emission warning, hazard-area warning lights and signs, restricted access, and key-control procedure.
126 +* Inspect the rack, marking head, fiber, objective, cables, connectors, and required labels for visible damage or unauthorized modification.
127 +* Keep the cooling openings clear and confirm that the environmental conditions are within the documented limits.
128 +* Start and verify the approved extraction system before any marking test.
129 +* Confirm secure work holding, correct focus, approved material and parameters, a clear hazard area, and qualified job data before enabling active mode.
130 +
131 +(% class="box errormessage" %)
132 +(((
133 +**Stop operation: **Do not use the Auto-Light if a safeguard, warning, enclosure component, circuit, acknowledgement, status signal, extraction system, label, or machine component is missing, damaged, bypassed, incorrectly adjusted, or behaving unexpectedly
134 +)))
135 +
136 +
137 +
138 += Response to a Safety-Device Fault =
139 +
140 +1. Stop the current operation and use the emergency stop if an immediate hazard exists.
141 +1. Switch off the Auto-Light and prevent unauthorized restart.
142 +1. Record the indicator state, software or host-machine message, affected safeguard, system model, and serial number.
143 +1. Inspect only to the extent permitted for trained operating personnel. Do not open the laser source or energized electrical compartments.
144 +1. Contact authorized service or the responsible integrator when the cause is not an approved operator-level correction.
145 +1. After repair, repeat the documented functional and validation checks before releasing the integrated machine for production.