... ... @@ -7,4 +7,41 @@ 7 7 8 8 ---- 9 9 10 += Auto-Light System Overview = 11 + 12 +* The laser rack contains the fibre-laser source and control hardware. 13 +* The marking head directs and scans the beam through the installed F-Theta lens. 14 +* The manual documents a 3 m fibre arrangement between the source and marking head. 15 +* A pilot laser supports workpiece positioning before production-laser emission. 16 +* An electrically controlled Z-axis establishes the required working distance in the documented configuration. 17 +* X1 connects external safety and production signals; X2 supports integrated X/Y/Z/R axis signals. 18 + 19 +[[**Auto-Light laser rack and marking head.**>>image:1788852299021-764.png]] 20 + 21 + 22 += Operator and Connection Panels = 23 + 24 +[[**Auto-Light front and rear panels. **>>image:1788852351064-324.png]] 25 + 26 + 27 +(% class="table-condensed table-striped" style="width:840px" %) 28 +|**Location**|(% style="width:628px" %)**Documented items** 29 +|Front panel|(% style="width:628px" %)Shutter / laser key switch; status indicator; USB interface; cooling-air openings. 30 +|Rear panel|(% style="width:628px" %)HDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input. 31 + 32 +(% class="box warningmessage" %) 33 +((( 34 + **Ventilation clearance: **Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage. 35 +))) 36 + 37 + 38 + 39 += Protective Devices = 40 + 41 +Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it. 42 + 43 +|**Device**|**Safety function and limitation**|**Required condition** 44 +|Main switch|Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure. 45 +|Shutter|Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine. 46 + 10 10
- 1788852351064-324.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +412.1 KB - Content