Änderungen von Dokument System Overview and Safety Devices

Zuletzt geändert von jadomatis am 2026/09/08 10:37

Von Version 1.2
bearbeitet von jadomatis
am 2026/09/08 09:27
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 3.4
bearbeitet von jadomatis
am 2026/09/08 09:35
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -7,4 +7,41 @@
7 7  
8 8  ----
9 9  
10 += Auto-Light System Overview =
11 +
12 +* The laser rack contains the fibre-laser source and control hardware.
13 +* The marking head directs and scans the beam through the installed F-Theta lens.
14 +* The manual documents a 3 m fibre arrangement between the source and marking head.
15 +* A pilot laser supports workpiece positioning before production-laser emission.
16 +* An electrically controlled Z-axis establishes the required working distance in the documented configuration.
17 +* X1 connects external safety and production signals; X2 supports integrated X/Y/Z/R axis signals.
18 +
19 +[[**Auto-Light laser rack and marking head.**>>image:1788852299021-764.png]]
20 +
21 +
22 += Operator and Connection Panels =
23 +
24 +[[**Auto-Light front and rear panels. **>>image:1788852351064-324.png]]
25 +
26 +
27 +(% class="table-condensed table-striped" style="width:840px" %)
28 +|**Location**|(% style="width:628px" %)**Documented items**
29 +|Front panel|(% style="width:628px" %)Shutter / laser key switch; status indicator; USB interface; cooling-air openings.
30 +|Rear panel|(% style="width:628px" %)HDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input.
31 +
32 +(% class="box warningmessage" %)
33 +(((
34 + **Ventilation clearance: **Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage.
35 +)))
36 +
37 +
38 +
39 += Protective Devices =
40 +
41 +Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it.
42 +
43 +|**Device**|**Safety function and limitation**|**Required condition**
44 +|Main switch|Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure.
45 +|Shutter|Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine.
46 +