Last modified by jadomatis on 2026/09/08 10:37

From version 1.1
edited by jadomatis
on 2026/09/08 09:24
Change comment: There is no comment for this version
To version 3.4
edited by jadomatis
on 2026/09/08 09:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,1 +1,47 @@
1 1  **Description**: The Auto-Light combines a modular laser rack and marking head with interfaces for externally integrated safety, production control, and motion control. Learn about the system hardware,  the protective devices, and safeguards that must be completed by the host machine.
2 +
3 +(% class="box errormessage" %)
4 +(((
5 +**Safety basis - Class 4 integration laser: **Auto-Light is not a self-contained Class 1 workstation. Do not release laser operation until the complete protective enclosure, access control, emergency-stop and shutter circuits, emission warning, extraction, and all configuration-specific protective measures have been installed, tested, validated, and documented.
6 +)))
7 +
8 +----
9 +
10 += Auto-Light System Overview =
11 +
12 +* The laser rack contains the fibre-laser source and control hardware.
13 +* The marking head directs and scans the beam through the installed F-Theta lens.
14 +* The manual documents a 3 m fibre arrangement between the source and marking head.
15 +* A pilot laser supports workpiece positioning before production-laser emission.
16 +* An electrically controlled Z-axis establishes the required working distance in the documented configuration.
17 +* X1 connects external safety and production signals; X2 supports integrated X/Y/Z/R axis signals.
18 +
19 +[[**Auto-Light laser rack and marking head.**>>image:1788852299021-764.png]]
20 +
21 +
22 += Operator and Connection Panels =
23 +
24 +[[**Auto-Light front and rear panels. **>>image:1788852351064-324.png]]
25 +
26 +
27 +(% class="table-condensed table-striped" style="width:840px" %)
28 +|**Location**|(% style="width:628px" %)**Documented items**
29 +|Front panel|(% style="width:628px" %)Shutter / laser key switch; status indicator; USB interface; cooling-air openings.
30 +|Rear panel|(% style="width:628px" %)HDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input.
31 +
32 +(% class="box warningmessage" %)
33 +(((
34 + **Ventilation clearance: **Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage.
35 +)))
36 +
37 +
38 +
39 += Protective Devices =
40 +
41 +Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it.
42 +
43 +|**Device**|**Safety function and limitation**|**Required condition**
44 +|Main switch|Controls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.|Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure.
45 +|Shutter|Interrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.|Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine.
46 +
47 +
1788852299021-764.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +455.0 KB
Content
1788852351064-324.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +412.1 KB
Content