System Overview and Safety Devices

Version 4.4 by jadomatis on 2026/09/08 09:51

Description: The Auto-Light combines a modular laser rack and marking head with interfaces for externally integrated safety, production control, and motion control. Learn about the system hardware,  the protective devices, and safeguards that must be completed by the host machine.

Safety basis - Class 4 integration laser: Auto-Light is not a self-contained Class 1 workstation. Do not release laser operation until the complete protective enclosure, access control, emergency-stop and shutter circuits, emission warning, extraction, and all configuration-specific protective measures have been installed, tested, validated, and documented.


Auto-Light System Overview

  • The laser rack contains the fibre-laser source and control hardware.
  • The marking head directs and scans the beam through the installed F-Theta lens.
  • The manual documents a 3 m fibre arrangement between the source and marking head.
  • A pilot laser supports workpiece positioning before production-laser emission.
  • An electrically controlled Z-axis establishes the required working distance in the documented configuration.
  • X1 connects external safety and production signals; X2 supports integrated X/Y/Z/R axis signals.
1788852299021-764.png

Auto-Light laser rack and marking head.

Operator and Connection Panels

1788852351064-324.png

Auto-Light front and rear panels. 

LocationDocumented items
Front panelShutter / laser key switch; status indicator; USB interface; cooling-air openings.
Rear panelHDMI; Ethernet; USB; X1 interface; X2 interface; main switch; mains input.

 Ventilation clearance: Keep approximately 15 cm clear at the cooling-air openings. Blocked airflow can cause heat accumulation and equipment damage.

Protective Devices

Only the main switch and shutter as protective devices on the Auto-Light. Other controls and interfaces support the safety concept but do not, by themselves, complete it.

DeviceSafety function and limitationRequired condition
Main switchControls the rack's electrical supply for normal start and shutdown. It is not a substitute for the site's required isolation procedure during electrical or service work.Must be accessible, undamaged, and used according to the approved start, shutdown, and isolation procedure.
ShutterInterrupts the laser beam when the integrated safety logic removes shutter permission. A closed shutter circuit enables active mode; it does not issue a marking command.Both external shutter channels, acknowledgement, guard logic, and beam-interruption response must be validated as part of the host machine.

Safety-Related Controls and Interfaces

Control / interfaceRole in the integrated system
Laser key switchHelps control authorized access to laser operation. Key control does not replace guarding or safety circuits.
Status indicatorSupports operating-state recognition. An indication alone is not proof that every safeguard is functional.
X1 emergency-stop circuitsProvides two external emergency-stop channels plus acknowledgement contacts for the host safety system.
X1 shutter circuitsProvides two external shutter channels plus acknowledgement contacts. Opening the protective enclosure must interrupt the shutter circuit.
X1 production/status I/OProvides external start/stop and emergency-stop, shutter, ready, busy, and end status signals. Production signals must never bypass safety permission.

Important Distinctions

  • The main switch is not an emergency-stop device and does not replace the required isolation procedure.
  • The shutter interrupts the beam, but it does not replace a complete laser-safe enclosure and access-control system.
  • The key switch helps prevent unauthorised operation, but it does not validate the safety chain.
  • Status outputs and indicators support control and diagnosis; they do not replace functional testing of safeguards.
1788852854245-428.png

Functional boundary between the host safety system and the Auto-Light.

How the Safety Chain Works

  1. The host safety system confirms that the protective enclosure is closed, access is controlled, and both emergency-stop and shutter channels are in the permitted state.
  2. The Auto-Light receives the validated safety state through X1. A closed shutter circuit permits active mode but does not start marking.
  3. The production controller may issue a start command only when the laser is ready and every process condition - including extraction, workholding, focus, and qualified job data - is satisfied.
  4. Opening a guarded access point or operating an emergency stop must remove the relevant permission and prevent continued laser emission according to the validated machine design.

Permission is not a command: A closed shutter circuit permits active mode. It must never initiate marking by itself, and it is not proof that the complete host safety system has been validated.

Safeguards Completed by the Host Machine

The system integrator and user company must establish the complete safety concept for the installed machine. At minimum, assess and implement the following requirements for the delivered configuration and installation site:

  • A laser-safe protective enclosure suitable for the installed wavelength, output, beam path, and foreseeable reflections.
  • Controlled access and guard monitoring that prevent exposure and interrupt the shutter circuit whenever the enclosure is opened.
  • An approved external safety module connected to both emergency-stop channels and both shutter channels through X1.
  • Emergency-stop devices, safe reset logic, acknowledgement behaviour, prevention of unexpected restart, and documented validation of the complete safety function.
  • External warning signs and warning lights identifying the Class 4 hazard area, plus an emission warning visible to the operator.
  • Restricted access and key control that prevent unauthorised operation.
  • Suitable extraction for gases, vapours, aerosols, and dust generated by the approved marking process.
  • Fire and explosion precautions appropriate to the workpiece, coating, residues, extraction system, and selected parameters.
  • Safe workholding, guarded axis motion, travel limits, homing behaviour, and production-control logic.
  • Training, written responsibilities, applicable personal protective equipment, and appointment of a laser safety officer where required by local regulations.

 Class 4 open operation: If the laser is operated without an effective protective enclosure, the entire controlled hazard area must be managed for Class 4 radiation. The manual requires restricted access, warning lights and signs, a visible emission warning, and laser safety glasses matched to the installed wavelength and power. These measures do not replace any additional legal or site-specific requirement.

Shutter and Emergency-Stop Behaviour

  • Opening the protective enclosure must interrupt the external shutter circuit.
  • Closing and validating the shutter circuit permits active mode; laser energy can be emitted only in active mode.
  • Emergency-stop acknowledgement through X1 is required at every system restart and after every emergency-stop actuation.
  • Acknowledgement may be accepted only after the cause has been removed and the hazard area is clear. It must not initiate laser emission or hazardous motion by itself.